Connecting to the RS-232C Port at the Host
S Connecting to the CS1 series serial communication board
INNER board with RS-232C port equipped for CS1 series CPU type :
CS1W-SCB41/21
[CPU allocation DM area settings]
Setting is written from the peripheral tool (a programming console or CX-Program-
mer) directly into the allocation DM area (system setting area) of the CPU. After
the setting is written, it becomes effective by turning the power ON, restarting the
unit, restarting the communication port, or execution of the STUP command.
In the following, the channel numbers of the allocation DM area and settings are
shown.
Allocation DM
area
H)
Port 1
Port 2
DM32000
DM32010
DM32006
DM32016
When connecting the PT with its model number 3–6 to port 1, for example, set the
value 8200 Hex to DM32000CH, and 0006 Hex to DM32006CH.
E
-
Writing Value
8200
NT link (1:N) mode
000
model number of the connected PT (0 – 7)