Omron NT631 Operation Manuals page 478

Programmable terminal
Hide thumbs Also See for NT631:
Table of Contents

Advertisement

Screen Display and Notification
Reference
[Operation]
Reference
[Example of Use]
- To display overlapping screens, specify the screen number of a parent screen.
- The screen is not switched if elements have not been registered to the specified
screen number.
(1) Press the touch switch with the screen switching function when the screen is
to be switched.
When the screen is changed over, the "screen switching strobe" of the PT status
notify bit changes to "1" (ON), after the new screen number is written to the "screen
switching setting area" in the PT status control area, so that the event of screen
switching is notified to the host. After that the "screen switching strobe" returns to
"0" (OFF) automatically.
[Screens other than No. 9999]
To next screen
"Screen number 5" is set for touch switch 1
[Screen No. 9999]
Menu Screen
Operation 1
Operation 2
When touch switch 1 is pressed
Screen switching
@ Instruction from host
@ Screen switchover key
Touch switch 1 pressed
Section 8-3
Screen number 5
Previous screen
"Screen number
9999" is set for
touch switch 1
471