RS-232
c. Interface with Gefen Syner-G™ via RS-232 ports of Sender and Receiver.:
1.
Direct interface with the Sender: Connect RS-232 Tx, Rx, and Ground from a computer
with a Serial (RS-232 port), or using a USB-to-RS-232 adapator, to the removable 3-pin
"Captive Screw" Phoenix connector that is attached to the RS-232 port of the Sender unit.
Each of the 3 pins is identified on the connector panel. If the Sender was configured to
be in "Remote-End-Control" mode (see section (b) on previous page), return it to its
default mode by following step (2) of section (b).
2.
Direct interface with the Receiver: Since the Receiver does not have any customizable
features , it cannot be used with Gefen Syner-G™.
3.
Interface with the Sender by connecting through the Receiver:
i.
Place the Sender unit in "Remote-End-Control" mode (see section (b) on previous
page for details). Wire the Sender unit as needed and install it in its location.
ii.
Make sure that the 3 position slide switch on the front panel of the Receiver is set to
RS-232 Pass-Thru mode.
iii.
Connect RS-232 Tx, Rx, and Ground from a computer with a Serial (RS-232 port), or
using a USB-to-RS-232 adapator, to the removable 3-pin "Captive Screw" Phoenix
connector that is attached to the RS-232 port of the Receiver unit.