CONTENTS Introduction Operation Notes Features Panel Layout Panel Descriptions Connecting and Operating The 4x1 DVI KVM DL/SL Switcher RMT-4IR Remote Control Description 4x1 DVI KVM DL/SL Switcher Remote Installation RMT-4IR Remote and 4x1 KVM Switcher Configuration EDID Modes DL (Dual Link) Only Modes RS-232 Serial Control RS-232 Serial Control Commands EDID Management Routing Commands...
The Gefen 4x1 DVI KVM DL/SL Switcher The rack-mountable Gefen 4x1 dual link/single link DVI KVM DL/SL Switcher offers an economical solution by eliminating the need to purchase many displays for each computer in a studio or lab situation.
OPERATION NOTES READ THESE NOTES BEFORE INSTALLING OR OPERATING THE GEFEN 4X1 DVI KVM DL/SL SWITCHER • The 4x1 DVI KVM DL/SL Switcher will take any of up to four (4) DVI dual- link or single-link resolution inputs and switch them, one at a time, to a DVI output device such as a display/monitor or projector.
FEATURES Features • Switches a workstation between any four computers with support for Dual- link or Single-link DVI, USB 2.0 and audio signals • Supports 1080p Full HD at 120Hz and dual-link resolutions up to 3840 x 2400 (WQUXGA) or single-link resolutions up to 1920 x 1200 (WUXGA) •...
PANEL DESCRIPTIONS External IR Port For connection of external IR extension device such as the Gefen IR Extender (part # EXT-RMT-EXTIR). IR Receiver Receives IR signal from the handheld Infrared remote control unit included with the 4x1 DVI KVM DL/SL Switcher.
Wiring Diagram for the 4x1 DVI KVM DL/SL Switcher DUAL LINK DVI CABLE AUDIO CABLE USB CABLE Computer Computer Computer Computer Dual Link DVI Display Switcher USB Mouse Powered EXT-DVIKVM-441DL Speakers USB Keyboard...
RMT-4IR REMOTE CONTROL DESCRIPTION LED Indicator Input Selection Buttons The RMT-4IR remote control will allow the user to choose which of the 4 DVI sources or computers will be selected. Please use the information below when selecting the desired source: RMT-4IR Button DVI Source...
4X1 DVI KVM DL/SL SWITCHER REMOTE INSTALLATION To use the RMT-4IR remote, remove the battery cover on the back of the remote to reveal the battery compartment. Insert the included battery into the open battery slot. The positive (+) side should be facing up. Ensure that both DIP (Dual Inline Package) switches are in the OFF position.
RMT-4IR REMOTE AND 4X1 KVM SWITCHER CONFIGURATION How to Resolve IR Code Conflicts In the event that IR commands from other remote controls conflict with the supplied RMT-4IR remote control, changing the remote channel will alleviate this issue. The RMT-4IR remote control and the 4x1 DVI KVM DL/SL Switcher both have banks of DIP (Dual Inline Package) Switches for configuring the remote channel that both units use to communicate. These settings must exactly match each other for proper operation.
EDID MODES What is EDID and what is it used for? Under normal circumstances, an audio/video source device (digital or analog) will require information about a connected device/display to assess what resolutions and features (capabilities) are possible. The source device can then tailor its output to create resolutions and/or features that are compatible with the attached device/display.
Page 15
EDID MODES EDID Modes The diagram below illustrates the 4-position DIP switch bank (containing 4 small white toggle switches as shown). The functions of the switches are as follows: DIP SWITCH Function IR Channel IR Channel EDID Mode 1 2 3 4 EDID Lock Mode Use DIP switch 3 to set the desired EDID mode.
DL (DUAL LINK) ONLY MODES DL (Dual Link) Only Modes The 8-position DIP switch bank located on the underside of the 4x1 DVI KVM DL/ SL Switcher can be used to set each individual input to work in a Dual Link Only mode.
RS-232 SERIAL CONTROL What features are available via the RS-232 serial communications port? The 4x1 DVI KVM DL/SL Switcher can accept commands through the RS-232 serial communications port located on the rear panel. The current RS-232 control features are the ability to switch/route inputs to outputs without the RMT-4IR remote control.
RS-232 SERIAL CONTROL COMMANDS RS-232 Features RS-232 remote functions are used to control of this product’s features. Features include input to output routing, EDID storage, EDID management, etc. Functions Syntax The syntax for each function is always the same: #Character as the start flag → Function name → Space ( _ ) as function name end flag → Parameter 1 → Space → Parameter n → Carriage Return ( \r ) →...
Page 19
RS-232 SERIAL CONTROL COMMANDS #EDIDDSTOLO Function The #EDIDDSTOLO function reads the downstream EDID and stores into all lo- cal inputs. Syntax: #EDIDDSTOLO Parameters: None #EDIDDSTOBA Function The #EDIDDSTOBA function reads the downstream EDID and stores it to a specified EDID bank. Syntax: #EDIDDSTOBA param1 Parameters: param1...
Page 20
RS-232 SERIAL CONTROL COMMANDS #DDCTODS Function The #DDCTODS function routes the input DDC to the downstream EDID (pass- through mode). Syntax: #DDCTODS Parameters: None #DDCTOLO Function The #DDCTOLO function routes the input DDC to the local EDID. Syntax: #DDCTOLO Parameters: None #DEF Function The #DEF function set the Switcher to the factory default settings.
Page 21
RS-232 SERIAL CONTROL COMMANDS #LOEDIDTOBA Function The #LOEDIDTOBA function loads the specified EDID file and stores it in a specified EDID bank. Syntax: #LOEDIDTOBA param1 param2 param3 Parameters: param1 Echo mode [0 - 1] Value Meaning Semi echo mode Full echo mode param2 EDID size [1 - 2] Value Meaning 128 byte EDID 256 byte EDID EDID bank offset [1 - 7] param3...
Page 22
RS-232 SERIAL CONTROL COMMANDS #LOEDIDTOLO Function The #LOEDIDTOLO function loads the specified EDID file to a specified local input. Syntax: #LOEDIDTOLO param1 param2 Parameters: param1 Echo mode [0 - 1] Value Meaning Semi echo mode Full echo mode param2 EDID size [1 - 2] Value Meaning 128 byte EDID 256 byte EDID #PRBAEDID Function The #PRBAEDID function reads the EDID file from the specified bank and sends it to the serial port.
Page 23
RS-232 SERIAL CONTROL COMMANDS #PRDSEDID Function The #PRDSEDID function reads the downstream EDID and sends it to the serial port. Syntax: #PRDSEDID param1 Parameters: param1 File type [0 - 1] Value Meaning .BIN file .TXT file #PRLOEDID Function The #PRLOEDID function reads the local EDID and spools it to the serial port. Syntax: #PRLOEDID param1 Parameters:...
RS-232 SERIAL CONTROL COMMANDS Commands Simplified syntax was used for command implementation for faster operation with the device: # character – isn’t needed, the command name is reduced to 1 letter. The commands are not case-sensitive. Command Description Displays the function menu Switch to Input 1 Switch to Input 2 Switch to Input 3 Switch to Input 4 The ASCII character table below indicates which Switcher input will be routed to...
Page 25
RS-232 SERIAL CONTROL COMMANDS 2. USING SHORT-CUT CHARACTERS TO CHANGE SETTINGS 2.1 HYPERTERMINAL SETTINGS in Microsoft Windows First, please set up the correct communication configuration by running these commands (as shown on the screen shot immediately below): File->Properties->Setting->ASCII Setup Also, please be sure to unmark the check box that says “Send line ends with line feeds.”...
RACK MOUNT INSTALLATION Rack mount ears are provided for installation of this unit into a 1U rack mount space. Locate the side screws on the unit. Remove the front 2 screws that are located closest to the front of the unit. Using the removed screws, screw the rack mounting bracket into the unit.
SPECIFICATIONS Video Amplifier Bandwidth:..............2 x 165 MHz Input Video Signal:................1.2 Volts p-p Input DDC Signal:................5 Volts p-p (TTL) Single Link Max. Resolution:..............1920 x 1200 Dual Link Max. Resolution:..............3840 x 2400 DVI Connector:............ DVI-I 29-pin female (digital only) Power Supply:....................5V DC Power Consumption........12.5 Watts (min.) / 22.5 Watts (max.) Dimensions:..............17.1”...
Gefen warrants the equipment it manufactures to be free from defects in material and workmanship. If equipment fails because of such defects and Gefen is notifi ed within two (2) years from the date of shipment, Gefen will, at its option, repair or replace the equipment, provided that the equipment has not been subjected to mechanical, electrical, or other abuse or modifi cations. Equipment that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair.