Trouble Shooting - Paramount Fitness PH-S-127 Instruction Manual

Cast aluminum patio heater
Table of Contents

Advertisement

If you are having this
problem
Burner flame will
not stay on
Burner flame
will not light
Igniter does not work
Please contact our Toll Free Hotline: 1-800-561-5550
Hotline hours: Mon. to Fri. 7:00am - 4:00pm ( P.S.T.)
TROUBLE SHOOTING GUIDE
If this condition exists:
1. Cylinder valve may be
OFF.
2. LPG tank empty
3. Orifice blocked
4. Loose connection
5. Thermocouple failed
6. Gas leak in line
7. Lack of fuel pressure
1. Pressure is low
2. Control not ON
3. Orifice blocked
Electrode might have
accumulated black soot
** IMPORTANT NOTICE***
Do NOT return to place of purchase!!!
for customer service and warranty issues
e-mail: customercare@jrhome.com

TROUBLE SHOOTING

You will need to do the following:
Open valve at cylinder. Turn cylinder
valve in counter-clockwise direction.
Refill LPG tank
Clean Spider web or other blockage,
or replace orifice.
Check all fittings
Replace thermocouple
Turn tank off. Wait 5 minutes.
Check fuel line connections.
Reinsert regulator tighten firmly
and re-try.
Refill fuel tank
Tank is near empty
Turn valve to ON and push in.
Remove and clean out.
Light the burner manually or clean
the electrode, check wire
connections and re-try.
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ph-s-126H0h1010-t-2

Table of Contents