The North American cable uses Black (Hot), White (Neutral), and Green (Ground).
The INTL part follows the international schema of Brown (Hot), Blue (Neutral) and Yellow/Green (Ground)
Please only use included or Aruba specified cables, power cords, AC power supplies and batteries. The power
!
cord should not be used with other electric equipment than what is specified by Aruba
Best Practice for Outdoor Connection to AC Mains
In all circumstances and with any outdoor infrastructure the recommended practice is to connect to AC mains in
an order grade weather protected junction box. This needs to be implemented by a qualified resource in a
manner that is consistent with the electrical code in force in the jurisdiction of deployment. In many countries
this will require a licensed electrician to perform this operation.
In Japan, this would is a Certified Electrician by Ministry of Economy, Trade and Industry.
The use of plugs with infrastructure equipment is suitable only for temporary installs where nuisance tripping of
GFI plugs is considered tolerable. Should it be desired to attach a plug to the cable assemblies then the installer
is expected to follow all directions provided with the plug end in a fashion consistent with local electrical code.
Use of the CKIT-OD-AC-P
Assembly instructions for this part are shipped with the part. All instructions must be followed to ensure proper
assembly of the connector onto the cable.
The required specifications for third party cable used with the CKIT solution are as follows:
AC power cable specifications (when using AC connector kit and custom cable): minimum voltage/current
rating 250V/1A, diameter 6-12mm, rated for outdoor use and UV exposure
AC Power Cable Connector PIN OUT
Figure 11
Connecting the Power Cable to the AP-275
1. Remove the weatherproof cap on the power interface.
2. Insert the power cable connector into the power interface and hand-fasten the locknut.

Verifying Post-Installation Connectivity

The integrated LEDs on the AP can be used to verify that the AP is receiving power and initializing successfully
(see
Figure 4
network connectivity.

Configuring the AP

Aruba AP-270 Series Outdoor Access Points
AC power cable connector
Neutral
Ground
and
Table
2). Refer to the ArubaOS Quick Start Guide for further details on verifying post-installation
| Installation Guide
Hot
11