Checking The Diode - Yamaha XG250 Service Manual

Hide thumbs Also See for XG250:
Table of Contents

Advertisement

▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Connect the pocket tester (DC 20 V) to the
turn signal relay terminal as shown.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
Positive tester probe
brown "1"
Negative tester probe
ground
b. Turn the main switch to "ON".
c. Measure the turn signal relay input voltage.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
2. Check:
Turn signal relay output voltage
Out of specification → Replace.
Turn signal relay input voltage
DC 12 V
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Connect the pocket tester (DC 20 V) to the
turn signal/hazard relay terminal as shown.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
Negative tester probe
brown/white "1"
Positive tester probe
ground
Br/W
Br
1
7-42
ELECTRICAL COMPONENTS
b. Turn the main switch to "ON".
c. Measure the turn signal relay output voltage.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
EAS28050

CHECKING THE DIODE

1. Check:
Diode
Out of specification → Replace.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
Continuity
Positive tester probe → blue/
white "1"
Negative tester probe → blue/
black "2"
No continuity
Positive tester probe → blue/
black "2"
Negative tester probe → blue/
white* "1"
L/B
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Disconnect the diode from the wire harness.
b. Connect the pocket tester (Ω × 1) to the di-
ode coupler as shown.
c. Check the diode for continuity.
Br/W
1
Br
1
L/W
L/B
2
L/W

Advertisement