2. Other Alarm Visual and Audible Indicators

Operational Mode
Visual Indications
normal (standby)
Green LED blink approx every 60 sec.
test (button press
4 patterns of Red/Amber/Green.
when no alarm
condition is present)
Test: Red LED blinks in time with
alarm pattern. Safety light will briefly
illuminate on model Q4000LDCS-
WCH or Q4000LDCS-WBH.
Green LED fade on/off at test
complete
smoke Alarm
Red and Amber LED alternate on
memory (unit has
1 sec, every 10 sec.
experienced a
smoke alarm event
within the last hour)
smoke Alarm hush
Red LED blinks every 2 sec.
mode, (smArt
hUsh control)
locate
None
smoke Alarm hush
None
mode cancelled
Initiating Alarm,
Red LED will flash on the unit
(multiple alarms in
initiating the alarm, but the red LED
an interconnected
on other interconnected units will
system)
not flash.
Audible Indications
Button press sound
Voice: "Testing, this is very loud. Press
now to cancel test. 5, 4, 3, 2, 1."
3 long beeps, Voice "Fire!", 3 long
beeps, Voice "Test Complete," Power
on/reset sound.
Voice "Test Cancelled" if button
pushed before test sequence
begins.
After button push: "Smoke previously
detected" only on the initiating
alarm unit.
After button push: "Hush Mode
Activated."
Smoke alarm pattern stops.
(If there is too much smoke to allow
Hush: Voice "Too Much Smoke, Alarm
cannot be Hushed" Smoke alarm
pattern continues.)
After button push on non-initiating
unit, only initiating unit continues
alarm pattern.
Voice message "Hush Mode
Cancelled."
Unit in Smoke Alarm mode.
Action/Note:
Perform Test/Hush button
press once a week to verify
proper alarm operation
Push/release button before
the countdown ends to
cancel test.
Push test button to clear
Alarm Memory. NOTE: stan-
dard test sequence will follow.
(Push/release button again to
cancel test).
This feature is to be used
only when a known alarm
condition, such as smoke from
cooking, activates the alarm.
Use this to quickly locate the
alarm source and determine if
alarm is nuisance or real.
When smoke levels drop
below the alarm threshold,
the voice message "Hush
Mode Cancelled" will occur .
Push button on initiating
alarm to silence that unit and
all interconnected units.
2