Photoelectric smoke alarms are designed to detect visible particles
(associated with slow smouldering fires). Home fires develop in different
ways and are often unpredictable. For maximum protection against fast
flaming fires and slow smouldering fires, both ionisation and photoelectric
alarms should be installed.
®
Quell
is a registered trademark of Chubb Fire & Security Pty Ltd
Copyright © 2020 carrier. All rights reserved.
Chubb Fire and Security Pty Ltd is part of the Carrier Global Corporation (NYSE: CARR)
group of companies.

Advertisement

Table of Contents
loading

Summary of Contents for Quell Simline QSP10

  • Page 1 ® Quell is a registered trademark of Chubb Fire & Security Pty Ltd Copyright © 2020 carrier. All rights reserved. Chubb Fire and Security Pty Ltd is part of the Carrier Global Corporation (NYSE: CARR)
  • Page 2: Table Of Contents

    Chubb Fire & Security Pty Ltd Building F Unit 1B 3-29 Birnie Ave, Lidcombe NSW, 2141 Australia Telephone : 1800 654 435 Website: www.quell.com.au Introduction Model QSP10 If you have any questions about the operation or installation of your alarm, please call 1800 654435.
  • Page 3 ・Mounting location :Ceiling or wall ・Sound Pattern:ISO8201(BI 0.5s-pause 0.5s-BI 0.5s-pause 0.5s-BI 0.5s-pause 1.5s, with the RED LED flashing, repeat this alarm pattern) ・Comply with:AS3786:2014 Warnings: ・To prevent injury, this apparatus must be securely attached to the ceiling/wall in accordance with the installation instructions.
  • Page 4 • For sloped, peaked or cathedral ceilings the alarm should be placed between 500mm and 1000mm from the highest point of the ceiling (Figure 2B). • Smoke alarms in rooms with ceiling slopes greater than 1m in 8m horizontally, should be located on the high side of the room (Figure 2B).
  • Page 5: Installation

    Installation DINING KITCHEN BEDROOM BEDROOM ROOM BEDROOM HALL BEDROOM LIVING ROOM BEDROOM LIVING KITCHEN ROOM Smoke Alarms for Minimum Protection Smoke Alarms for Additional Protection Ionisation Type Smoke Alarm with Alarm BASEMENT Silencer (Hush ® ) or Photoelectric Type SINGLE FLOOR PLAN MULTIPLE FLOOR PLAN FIGURE 1A FIGURE 1B...
  • Page 6 Installation Figure 2A 500mm NOT IN THIS AREA 1000mm DEAD AIR ANYWHERE IN THIS AREA DO NOT INSTALL PEAK CEILING Figure 2B 500mm NOT IN THIS AREA 1000mm ANYWHERE IN THIS DEAD AIR AREA DO NOT INSTALL SLOPED CEILING...
  • Page 7 Installation Do Not Install Smoke Alarm Devices In The Following Places: 1. In the garage. Products of combustion are present when you start your automobile. 2. Less than 20" (50cm) from the peak of an “A” frame type ceiling. (See figure 2A) 3.
  • Page 8 Installation ・Place the mounting plate on the desired installation Iocation and mark where the holes should be drilled. ・Drill two holes with adiameter of 5 millimetres. ・Push the plastic plugs into the holes. ・Remove the fixing plug from the mountingplate (if necessary, use a screw driver for this).
  • Page 9 Installation...
  • Page 10: Operation

    Operation Product function description: Function Indication Description Standby The red LED flashes The unit is working. status every 40 seconds. Low battery The unit chirps with The battery is under warning red LED flashing every low battery status, 40 seconds. please replace the smoke alarm device.
  • Page 11 Operation Product function description: Function Indication Description Weekly The unit chirps weekly. Self-test instead of self-test testing weekly by manual. Recommend testing the alarm semiannually by pressing the TEST button. Silence The Red LED flashes This smoke alarm has function every 8 seconds.
  • Page 12 Operation Product function description: Function Indication Description No disturbing The Red LED flashes The unit will stop every 40 seconds. nuisance warning about 10 hours under low battery or fault mode when the HUSH button is pressed. CAUTION: Before using the silence function, identify the source of the smoke and make sure a safe condition existing.
  • Page 13 Operation...
  • Page 14 Operation Disassembling Instructions 1 To disassemble the smoke alarm, take a screw driver and push it into the mounting hole. Then, turn the smoke alarm counterclockwise to remove it from the mounting bracket. Disassembling Instructions 2 No tools required, Turn the alarm body counterclockwise and take out the alarm body from the bracket.
  • Page 15: Troubleshooting

    Trouble shooting: Cause and Remedy Problem • The red LED does not Make sure the product is flash very 40s activated • Smoke alarm does not Make sure the product is sound when tested activated • Clean the smoke alarm. •...
  • Page 16: Maintenance

    Maintenance In addition to weekly testing, the alarm requires periodic cleaning to remove dust, dirt, and debris. Clean the alarm at least once a month to remove dust, dirt, or debris. Use a vacuum cleaner with the soft brush, vacuum all sides and covers of smoke alarm device.
  • Page 17: Fire Safety

    Fire Safety WARNING: Please read carefully and thoroughly. • Australian Standard AS 1670.6 states the purpose of installing smoke alarms is to provide early warning of a potentially life threatening condition and provide the maximum possible exit time. • Smoke alarms have sensing limitations. Ionisation sensing alarms may detect invisible fire particles (associated with fast flaming fires) sooner than photoelectric alarms.
  • Page 18 Fire Safety Additional Information Smoke Detection - Where required by applicable laws, codes, or standards for the specified occupancy, approved single and multiple-station smoke alarms shall be installed as follows: • In all sleeping rooms with the exception: Smoke alarms shall not be required in sleeping rooms in existing one and two-family dwelling units.
  • Page 19: Good Safety Habits

    Installation Date: Alarm Model(s): Installer/Landlord: Tel: Chubb Fire & Security Pty Limited ABN 47 000 067 541 Building F Unit 1B, 3-29 Birnie Ave, Lidcombe NSW, 2141 Australia www.quell.com.au...
  • Page 20: Warranty & Contact Details

    5 years from the date of purchase. To the extent permitted by law, Quell agrees to repair or replace (at our discretion) any defective product on presentation of the proof of purchase.