Quell Q1300 Owner's Manual

240v interconnectable main operated alarm
Hide thumbs Also See for Q1300:

Advertisement

240V Interconnectable Main Operated Alarm
Thank you for purchasing Quell 240V hard-wired photoelectric
smoke alarm. Please read through our guide in full. It should be
retained for future reference.
Cut out page 10 and pin up near your Consumer Unit/Fuse
Box.
Chubb Fire & Security Pty Limited recommends for maximum
protection that both ionisation and photo-electric (optical) smoke
alarms be installed. Ionisation sensing alarms may detect
invisible fire particles (associated with fast flaming fires) sooner
than photoelectric alarms. Photoelectric sensing alarms may
detect
visible fire particles (associated with slow smouldering
fires) sooner than ionisation alarms. Home fires develop in
different ways and are often unpredictable.
Electrical rating 240V AC,
50Hz 80mA max per alarm
(maximum 80mA for originating unit
with 24 Devices interconnected).
Chubb Fire & Security Pty Limited
149-155 Milton Street, Ashfield NSW 2131, Australia
INSTALLER, PLEASE LEAVE IN SAFE PLACE FOR HOUSEHOLDER
SAVE THIS MANUAL FOR FUTURE REFERENCE
Ownerʼs
www.quell.com.au

Smoke alarm

Manual
For models: Q1300
P/N:130413, 132819
1385-7209-02

Advertisement

Table of Contents
loading

Summary of Contents for Quell Q1300

  • Page 1: Smoke Alarm

    Ownerʼs 240V Interconnectable Main Operated Alarm For models: Q1300 Thank you for purchasing Quell 240V hard-wired photoelectric smoke alarm. Please read through our guide in full. It should be retained for future reference. Cut out page 10 and pin up near your Consumer Unit/Fuse Box.
  • Page 2: Table Of Contents

    Contents Section 1. Important Information..........1 Section 2. Types of Alarm............2 Section 3. How to Operate/Test the Alarm........3 Section 4. Battery Checking/Changing........4 Section 5. Maintenance............6 Section 6 What to do in an Emergency........6 Section 7. Troubleshooting............7 Section 8. Useful Hints............8 Section 9. Limitation of Smoke Alarms........8 Section10.
  • Page 3: Important Information

    ENVIRONMENTAL PROTECTION Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice. 1. Important Information This alarm is designed for installation by a qualified (licensed) electrician, in accordance with current Building Code of Australia (BCA) Regulations and to any other local or building codes that may apply.
  • Page 4: Types Of Alarm

    AC/DC alarms 240V mains – for professional installation. Minimum required to comply with relevant local Building Regulations. Interconnectable to other Quell Alarms, so all will sound when one is triggered. If mains power is lost, will operate via battery power if batteries are fresh/properly installed.
  • Page 5: How To Operate/Test The Alarm

    • Optical (Photo-Electric) alarms are less prone to nuisance alarms from cooking fumes. They are therefore the recommended type in AS3786, for fitting near kitchen areas and on escape routes/circulation spaces. Clear Air Light Photosensitive Lens Source Cell Smoke AS3786 recommend however, that optical alarms are also used especially in locations where steam or cooking fumes, from a nearby room could cause nuisance alarms.
  • Page 6: Battery Checking/Changing

    (Do not stand too close to the Immediately after alarm during testing – hearing may be damaged). completing the test cycle, the Q1300 models will enter into Hush mode and the red LED will flash approximately every 10 seconds (refer to section c. Hush Button).
  • Page 7: Battery Change

    b. Battery Change Firstly isolate the mains supply at the consumer unit by identifying the appropriate circuit. This may be a dedicated fuse marked “Fire/Smoke Alarms” or with a symbol such as (If you rent your property, your Landlord may arrange this service for you).
  • Page 8: Maintenance

    5. Maintenance • Your alarm is a life saving device. Spending a few minutes each month in vacuuming off any excess dust will enhance its performance and reduce the likelihood of nuisance alarms. • Vacuum up to the grill and through the slots where dust/talc etc. can enter.
  • Page 9: Troubleshooting

    >. Check via Test Button. Interconnected See part 1b above – consult a qualified electrician alarms do not sound or your Landlord to remedy as soon as possible. when test button is pressed and held. Consult our website for additional information and help www.quell.com.au...
  • Page 10: Useful Hints

    8. Useful Hints • Smoke alarms can only operate correctly if smoke particles reach the unit. Correct selection/siting and installation are covered in the installers manual. • With the exception of garages/kitchens/bathrooms it is recommended that smoke alarms are fitted in every room and outside all sleeping areas.
  • Page 11 Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need to escape, followed by the appropriate egress actions by those occupants. If the alarm is located outside the sleeping room or on a different floor, it may not wake up a sound sleeper. The use of alcohol or drugs may also impair oneʼs ability to hear the smoke alarm.
  • Page 12: Section10. Good Safety Habits

    Chubb Fire & Security Pty Limited ABN 47 000 067 541 A UTC Climate, Controls & Security Company 149-155 Milton Street, Ashfield NSW 2131, Australia www.quell.com.au Chubb New Zealand Limited A UTC Climate, Controls & Security Company 3 Fisher Crescent, Mt Wellington, Auckland, New Zealand www.chubb.co.nz...
  • Page 13: Section11. Warranty & Contact Details

    11. Warranty & Contact Details TEN YEAR LIMITED WARRANTY Warranty Chubb warrants to the original consumer purchaser that each new smoke alarm will be free from defects in materials and workmanship under normal use for a period of 10 years from the date of purchase.
  • Page 14 ABN 47 000 067 541 A UTC Climate, Controls & Security Company 149-155 Milton Street, Ashfield NSW 2131 Australia Telephone: 1800 654 435 Website: www.quell.com.au Chubb New Zealand Limited A UTC Climate, Controls & Security Company 3 Fisher Crescent, Mt Wellington, Auckland, New Zealand Telephone: 09 270 7288 Website: www.quell.co.nz...

Table of Contents