Symbol
on the display
INVERTED PAIR
Symbol
on the display
CROSSED PAIRS
Symbol
on the display
GENERIC ERROR
(MISWIRE)
Symbol
on the display
SPLIT PAIRS
The instrument identifies the SPLIT error, making the concerned pairs flash
and showing symbol
The error condition SPLIT is detected by the instrument only in case no
other error condition is present and with a cable length of at least 5m (15ft).
Cables of pair 3-6 inverted
Cables of pair 3-6 crossed
with cables of pair 4-5
Cables
of
pair
inverted
Cable 4 of the pair 4-5
short-circuited
cable 8 of pair 7-8
Screen S open
Correspondence pin to pin
is maintained, but the
cables of pairs 3-6 and 4-5
are physically crossed
CAUTION
SPLIT
on the display.
"
"
EN - 10
QUICKLAN 6050N
1-2
with
Need help?
Do you have a question about the QUICKLAN6050N and is the answer not in the manual?