REPLACEMENT OF THE PRESSURE SWITCH
NOTE: It must NOT be adjusted or tampered with. Also note that the operation of the pressure switch is dependant
on the venturi and its tubes being clean and clear of any debris or obstructions. It may be necessary to check and
clean the venturi with a pipe cleaner or similar article, which may eliminate any cycling problems.
1. Repeat operations 1 – 2 for removal of the fan housing.
2. Unplug the connector block to the pressure switch. Refer to fig. 6.
3. Remove the two tubes from the pressure switch outlets.
4. Undo and remove the retaining nuts holding the pressure switch in place.
5. Fit replacement unit and re-assemble by following the relevant part in section nine.
6. Restore electrical supply and re-commission appliance.