SECTION FIVE Replacement Parts (user instructions)

The only user removable parts are: -
The loose pebbles or coals.
The left hand front pebble or coal shape
The right hand front pebble or coal shape.
The base matrix
Cast Fret
Decorative Trim

SECTION SIX Appliance Specification (installation instructions)

Data Label Location, Natural Gas & LPG:
Gas Connection, Natural Gas & LPG:
Length of Flue
Length of Flue Pipe (Supplied) 435mm, 1 metre length available as an optional extra.
Category of Appliance:
Category
Gas type:
Gas Pressure:
Gas input high:
Gas input low:
Injector Main:
Oxy-pilot
NOTE: The efficiency of this appliance has been measured as specified in BS7977-1 2009 + A1:2013 and the result is 50.9%. The gross calorific
value of the fuel has been used for this efficiency calculation. GasTec have certified the test data from which it has been calculated. The
efficiency value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
www.charltonandjenrick.co.uk
Top behind decorative trim.
NATURAL GAS VERSION
B
AS
I
2H
G20
20 mbar
7.00kW Gross
2.40kW Gross
Size 460
NG9040
8 mm OD Tube.
1 metre (max).
PROPANE GAS VERSION
15
B
AS
I
3P
G31
37 mbar
7.00 kW Gross
2.40 kW Gross
Size 135
LPG9222
LT5052 (ISS 5)