Instruction for user,
Installation & Servicing
PARAGON
P10
Keep this booklet for service log and future reference
IMPORTANT
This appliance is guaranteed for 12 months subject to conditions. The 5 year extended parts
warranty will only be valid if the annual service recommended in this manual has been
completed and appliance has been registered online.

Advertisement

Table of Contents
loading

Summary of Contents for Paragon P10

  • Page 1 Instruction for user, Installation & Servicing PARAGON Keep this booklet for service log and future reference IMPORTANT This appliance is guaranteed for 12 months subject to conditions. The 5 year extended parts warranty will only be valid if the annual service recommended in this manual has been...
  • Page 2: Table Of Contents

    Benchmark Scheme ................................2 Introduction ..................................3 Consumer Protection Information ............................ 3 To light the appliance using the remote handset: ...................... 5 Cleaning the P10 Appliance ............................6 Fuel Bed Layout ................................. 7 Technical Specification ..............................15 Siting the Appliance ............................... 16 Commissioning the Appliance ............................
  • Page 3: Benchmark Scheme

    Benchmark Scheme Charlton and Jenrick Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance.
  • Page 4: Introduction

    P10 USERS INSTRUCTIONS Introduction The P10 has been designed and tested to the requirements of EN 613 and is suitable for use in Great Britain & Republic of Ireland. P10 incorporates a single gas valve which selects ignition pilot, with variable setting between low and high setting and is operated via remote control hand device or optional smart app device.
  • Page 5 P10 USERS INSTRUCTIONS Important Information The appliance is for use on Natural Gas (G20 @ 20mbar) or LPG (G31 @ 37mbar). The Chimney or flue (unless new or previously used with a gas appliance) shall be swept before installation if been used for solid fuel.
  • Page 6: To Light The Appliance Using The Remote Handset

    P10 USERS INSTRUCTIONS To light the appliance using the remote handset: Point the remote control handset in the direction of the appliance and simultaneously press the buttons marked ‘ off’ and ‘standby’. Continue to hold in these two buttons until a ‘bleep’ is heard (approximately 2-3 sec.) and then release these...
  • Page 7: Cleaning The P10 Appliance

    Remove the cover from the rear of the handset and fit replacement batteries, taking note of the orientation. Cleaning the P10 Appliance Ensure the appliance is cold before proceeding. The outer metal work frame should be cleaned using a damp cloth.
  • Page 8: Fuel Bed Layout

    P10 USERS INSTRUCTIONS Cleaning the fuel bed shapes. (Please refer to customer protection information on page 3 of this booklet before cleaning or replacing any refractory materials). The fuel bed components are delicate and they should be handled with great care. They can be brushed very gently with a soft brush to remove dust or any deposits.
  • Page 9 P10 USERS INSTRUCTIONS RH Inlet Cover LT8540 P a g e...
  • Page 10 P10 USERS INSTRUCTIONS Please note to maintain an even flame picture across the burner assembly. All outlet port banks need to be clear of any loose vermiculite in the area highlighted below. No 2 Shape LT8540 P a g e...
  • Page 11 P10 USERS INSTRUCTIONS No 3 Shape LT8540 P a g e | 10...
  • Page 12 P10 USERS INSTRUCTIONS No 4 Shape No 5 Shape No 6 Shape LT8540 P a g e | 11...
  • Page 13 P10 USERS INSTRUCTIONS No 7 Shape No 8 Shape No 9 Shape LT8540 P a g e | 12...
  • Page 14 P10 USERS INSTRUCTIONS No 10 Shape No 11 Shape No 12 Shape LT8540 P a g e | 13...
  • Page 15 P10 USERS INSTRUCTIONS No 13 Shape No 14 Shape No 15 Shape LT8540 P a g e | 14...
  • Page 16: Technical Specification

    P10 INSTALLATION INSTRUCTIONS Technical Specification Model Working Front Country Type Pressure Injector Input Class Pilot Natural 7.7 KW 2900 GB, IE mbar Gross 7.0 KW 9264 GB, IE Mbar Gross Efficiency Class 1 Gas Inlet Connection Size 8mm Handset Replacement Batteries 2 x AAA 1.5V Power Supply Type Plug –...
  • Page 17: Siting The Appliance

    P10 INSTALLATION INSTRUCTIONS Packaging Check List 1 x Glass Panel 1 x Boxed Fuel Bed 1 x Transformer Plug 1 x RF Handset 2 x AAA 1.5V Batteries Siting the Appliance Regulation and warnings This appliance must only be installed in Great Britain and Eire.
  • Page 18 The P10 is designed to be fitted into a class one flue with a fire place which will require a 50mm rebate. The other option is hole in the wall which can be plastered up to the edge of the fire place frame or fitted with wall mounted non-combustible slips.
  • Page 19 Fit the fire place frame to the fire box flange. The fireplace surround can now be constructed. The P10 can be installed using three different methods when going hole in the wall. A- Hole in the wall using none combustible slips.
  • Page 20 P10 INSTALLATION INSTRUCTIONS A- B-C / Builder’s opening aperture size when fitting hole in the wall boarded edge or slips. A-Hole in the wall using none combustible slips. LT8540 P a g e | 19...
  • Page 21 P10 INSTALLATION INSTRUCTIONS Using rawl plugs and wood screws retain the fire box via the 6mm holes within the slip brackets. None combustible slips can now be fitted up to the edge of the fire place frame. B-Dry lined hole in the wall.
  • Page 22 P10 INSTALLATION INSTRUCTIONS Open the aperture size to accommodate the fire box as out lined at the beginning of the section. With the height of the opening established and support for the fire box in place, take out a further area of the plaster board lining to expose the inner brick work face of the chimney breast as out lined in Fig 1.
  • Page 23 No combustible material should be fitted inside the fireplace opening. Installation with a flexible liner The P10 is designed for installation within the masonry chimney with or without a flexible line. *please note the restrictor plate is fitted to the firebox outlet and should not be removed subject to a successful spillage test If the flexible liner option is required the following two methods should be followed.
  • Page 24 P10 INSTALLATION INSTRUCTIONS Offer the fire box assembly within the masonry aperture at the same time guiding the gather hood within the guides situated on the top of the fire box (Please see picture below). Engage the hood studs within the slotted holes and secure using the three M4 nuts provided within the gather hood kit.
  • Page 25 P10 INSTALLATION INSTRUCTIONS Gas supply routing. Check the gas run to assess that the gas supply is capable of providing the required amount of gas and is in accordance with the rules in force. Soft copper pipe can be used to install the appliance. Soldered joints can be used only externally of the appliance.
  • Page 26 P10 INSTALLATION INSTRUCTIONS Power lead routing The power supply for this appliance is provided via AC power adaptor 230 VAC. The main cable terminates at the rear Right hand side of the fire box. The length of the cable provided with the appliance is 1.65 metres.
  • Page 27 P10 INSTALLATION INSTRUCTIONS The battery manual override option is a backup supply in case of a power failure / power cut to the property. The battery holder and adaptor lead sold separately. (Please note that the “C” cell batteries are not included). It is good practice to demonstrate the battery option to the customer during the commissioning process.
  • Page 28 P10 INSTALLATION INSTRUCTIONS Important When fitting the fireplace frame the studs need to be fully engaged to the top of the keyhole slot (as shown). If this is not fully engaged, it may cause ignition and outing issues Keyhole slot must be fully engaged to maintain...
  • Page 29: Commissioning The Appliance

    P10 INSTALLATION INSTRUCTIONS Commissioning the Appliance Checking gas soundness and running pressure. Turn on the supply to the appliance and check for soundness in accordance with the current codes of practice. Turn off the gas supply at the external isolation valve.
  • Page 30 P10 INSTALLATION INSTRUCTIONS Spillage Test Procedure. Light the appliance on maximum setting. Close all the doors and windows. After five minutes fit the smoke match within match holder and position as illustrated in Figure 13 with the head of the match just inside the inlet air channel.
  • Page 31 P10 INSTALLATION INSTRUCTIONS Advise The Customer. The glass front of this fire acts as a dress guard conforming to BS 1945 (1997) and satisfies the heating appliance regulations (1991) however; a fireguard conforming to BS6539 (1997) must be used to protect young children, the elderly, or infirm.
  • Page 32: Annual Service Requirement

    P10 SERVICE / FAULT FINDING INSTRUCTIONS Annual Service Requirement. General Servicing should be carried out annually by competent person whose name appears on the gas safe register. All Gas Safe engineers should possess an ID carrying the logo below. Before commencing any service or replacement of part, turn off the gas supply to the fire. After servicing check for gas soundness.
  • Page 33 P10 SERVICE / FAULT FINDING INSTRUCTIONS With the covers removed. The catchment area at the rear of the fire box can now be inspected for debris. With the aid of a mirror via the back of the box check the path of the flue for any restrictions.
  • Page 34: Fault Finding Charts

    P10 SERVICE / FAULT FINDING INSTRUCTIONS Fault Finding Charts LT8540 P a g e | 33...
  • Page 35 P10 SERVICE / FAULT FINDING INSTRUCTIONS LT8540 P a g e | 34...
  • Page 36 P10 SERVICE / FAULT FINDING INSTRUCTIONS LT8540 P a g e | 35...
  • Page 37 P10 SERVICE / FAULT FINDING INSTRUCTIONS Wiring Diagram LT8540 P a g e | 36...
  • Page 38: Maintenance

    P10 MAINTENANCE INSTRUCTIONS Maintenance To Remove the Burner Carrier Assembly Remove the glass panel as described on page 6 of the users instruction section. Remove the Loose shapes. Remove the two screws retaining the burner Assembly. Shut off the restrictor elbow and disconnect the 8mm inlet nut.
  • Page 39 P10 MAINTENANCE INSTRUCTIONS Replacement of The Gas Valve Follow the sequence to remove the burner carrier assembly. Disconnect the thermocouple from the rear of the gas valve. Undo the three compression nuts securing the pipes to the gas valve and remove the two M4 nuts fixing the valve to the valve mounting brackets.
  • Page 40 P10 MAINTENANCE INSTRUCTIONS Replacement of the Burner Assembly Remove the glass panel as described on page 6 of the users instruction section. Remove the Loose shapes. Undo the two fixing screws retaining the burner assembly with the carrier. Lift the burner clear of the silencer and injector tip.
  • Page 41 P10 MAINTENANCE INSTRUCTIONS Replacement Handset Follow the guide stipulated on page 6 of the users instructions “Changing the handset batteries” to load the batteries into the new handset. Re-Pairing the handset or ECU unit When replacement handset or ECU the two items will need to be re-paired using the following procedure.
  • Page 42: Your Fire Years Parts Extended Warranty

    Your Fire Years Parts Extended Warranty P10 WARRANTY DETAILS Please read it carefully and ensure your installer has filled in the gas commissioning checklist, keep it in a safe place so that it is available when your Gas Safe engineer carries out the annual service.
  • Page 43: Four Year Service Log Details

    Four Year Service Log Details The following information must be completed to support by receipts as part of the conditions of the extended five year parts warranty and the appliance must be registered by completing and return the registration document (last page of this booklet) to Infinity Fires. Date of first service...
  • Page 44: Gas Fire Commissioning Checklist

    GAS FIRE COMMISSIONING CHECKLIST This Commissioning Checklist is to be completed in full by the competent person who commissioned the gas fire as a means of demonstrating compliance with the appropriate Building Regulations and then handed to the customer to keep for future reference. Failure to install and commission according to the manufacturer’s instructions and complete this Benchmark Commissioning Checklist will invalidate the warranty.
  • Page 45: Register Your 12 Month Warranty With Us Today

    Register Your 12 Month Warranty with Us Today www.charltonandjenrick.co.uk/warranty. To register your appliance at Installer Details Name Company name Gas safe number Date of installation Your Details Name Address Post Code Telephone No Product Details Model : 620 HD Serial No Date of Purchase This information can be found on the label attached to the packaging and on the data badge.
  • Page 46 LT8540 P a g e | 45...
  • Page 47 LT8540 P a g e | 46...
  • Page 48 Paragon P10 Packing List P10 NG A-0866 – Glass Liners Fitted Pre- Fix A-0855 – Black Ribbed Liners P10 LPG -Glass Liners Fitted Pre-Fix -Black Ribbed Liners Data Badge On Plate Burner Tray / Firebox Assembly Air test Completed Grommet (1092)