Download Print this page

Paragon TURBO PLUS LPG User Instructions

Decorative fuel-effect gas fire

Advertisement

Quick Links

SECTION ONE
Consumer Protection Information
As manufacturers and suppliers of heating products, we take every care, as far as is reasonably
practicable, that these products are so designed and constructed as to meet the general safety
requirement when properly used and installed. To this end, our products are thoroughly tested
and examined before despatch.
IMPORTANT NOTICE: Any alteration that is not approved by the appliance manufacturer
could invalidate the approval of the appliance, operation of the warranty and could affect your
statutory rights.
Health and Safety Notice
Important
This appliance could contain some of the materials, indicated below, that could be interpreted
as being injurious to health and safety. It is the users / installers responsibility to ensure that the
necessary personal protective clothing is worn when handling these materials, see below for
information.
Artificial Fuels, Mineral Wool, Insulation Material, Refractory/Ceramic Fibres, Glass Yam -
if
may be harmful
inhaled, may be irritating to skin, eyes, nose and throat.
When handling
avoid inhaling and contact with skin or eyes. Use disposable gloves, facemasks and
eye protection. After handling wash hands and other exposed parts. If a vacuum is used for cleaning the
coals or cleaning after servicing / installation it is recommended that it be of the type fitted with a HEP A
filter.
Disposal of refractory/ceramic materials.
be securely wrapped in polythene and be clearly labelled 'RCF
'hazardous waste and should be disposed of at a site licensed for the disposal of industrial waste.
The PARAGON TURBO PLUS LPG is a fan flued decorative fuel-effect gas fire, which does
not require a chimney but must be installed on a suitable outside
It is important that the fan outlet, protected by the terminal guard, is kept clear at all
times.
The PARAGON TURBO
European Standard EN 509.
The appliance is for use on Propane Gas only and requires a 220-240V 50Hz electrical
supply protected by 3A fuse. It should only be installed by a competent person Le. CORGI-
registered,
in
accordance
REGULATIONS and
Like all appliances
frequency noise may be heard.
It is advised that the PARAGON TURBO PLUS LPG fanned flued fire is serviced annually as
it is more likely to provide trouble-free operation.
The flue be regularly checked and kept clear of any obstruction.
PLUS LPG is designed and tested to the requirements
with
the
I.E.E.
WIRING REGULATIONS.
incorporating
an aerated burner with a fanned flue system a low
User's Instructionsl
To keep dust to a minimum these materials should
waste'.
These materials are not classified as
GAS
SAFETY
(INSTALLATION
wall.
AND
57922
of the
USE)

Advertisement

loading

Summary of Contents for Paragon TURBO PLUS LPG

  • Page 1 • It is advised that the PARAGON TURBO PLUS LPG fanned flued fire is serviced annually as it is more likely to provide trouble-free operation. •...
  • Page 2 SECTION ONE • The fire does not normally require purpose-built ventilation but if for any special reason purpose-built ventilation is provided it should be checked periodically to ensure freedom from obstruction. • Rubbish must not be thrown onto the coal bed under any circumstances. •...
  • Page 3: Section Two

    User's Instructions\ SECTION TWO • The PARAGON TURBO PLUS LPG is a decorative fuel-effect gas fire designed for use in locations, which do not have a conventional chimney. This is achieved by extracting the products of combustion of the fire using a centrifugal fan via a ducting system connected through an outside wall.
  • Page 4 User's Instructionsl SECTION THREE LIGHTING THE FIRE Push the control knob in as far as possible on gas control. Turn knob anti-clockwise until a click is heard. The knob will stop at the position marked and a spark should be seen at the tip of the ignition probe. At the same time the pilot flame should light.
  • Page 5 User's Instructionsl SECTION FOUR Ensure the REAR MATRIX is in position as shown in Fig. 1. Ensure the REAR MATRIX is positioned in the location stop on the angled legs as shown Ensure the CENTRE MATRIX locates FIG.2 into the burner and rests on the rear back slip of the burner as shown in Fig.
  • Page 6: Section Five

    SECTION FOUR Lay loose coals as shown in figsA to 7. 116165 POSITION 4 SMALL COALS SO THAT POSITION 4 LARGE COALS THEY ARE AGAINST THE FIREBACK FORMING A LINE EVENLY SPACED ONE IN EACH CORNER AND TWO AS SHOWN EVENLY SPACED BETWEEN POSITION 5 SMALL COALS SO THAT POSITION 4 SMALL COALS SO THAT...