  • Page 1 PARAGON SYMPHONY CF OWNER MANUAL INCLUDES USER INSTRUCTION & INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is for use in Great Britain or...
  • Page 2: Table Of Contents

    Paragon Symphony CF Instructions CONTENTS PAGE USERS INSTRUCTIONS SECTION ONE Introduction Consumer Protection Information Heath & Safety Notice Introduction Important Information SECTION TWO Operating Appliance Lighting the Appliance Replacing Hand Set Battery Replacing Appliance Battery SECTION THREE Cleaning Cleaning Trim and Fret or Fascia...
  • Page 3: Section One

    ‘hazardous waste and should be disposed of at a site licensed for the disposal of industrial waste. INTRODUCTION • The PARAGON SYMPHONY CF as been designed and tested to the requirements of EN 613 and is suitable for use in GB (Great Britain) and IE (Ireland). •...
  • Page 4: Important Information

    SECTION ONE Introduction Continued The PARAGON SYMPHONY CF is battery operated; therefore no mains electrical supply is required. Power to the appliance is provided by 6 high power alkaline 1.5V batteries (AA size) (a spare set of 6 AA batteries is supplied with the appliance); these batteries can be changed to Nickel Metal Hydride rechargeable batteries providing they have a minimum capacity of 2200 mAh.
  • Page 5: Section Two

    Paragon Symphony CF Users Instructions SECTION ONE Introduction Continued • Care must be taken to prevent any damage being caused to surrounding soft furnishing or decoration; e.g. many embossed vinyl wall coverings may become discoloured if placed too close to the appliance. Combustible material i.e. wall panelling or wallpaper must be removed from behind the fire and fire trim.
  • Page 6: Lighting The Appliance

    Paragon Symphony CF Users Instructions SECTION TWO Operating the Appliance Continued TO REPLACE BATTERY IN HAND SET (9V SIZE MN1604 OR 6F22) Remove the cover from the rear of the handset and fit replacement battery. Take care not to stain the battery connections.
  • Page 7: Section Three

    Note: - Take care when cleaning in this area so as not to damage the pilot assembly. GLASS CLEANING From time to time it will be necessary to clean the glass panel of your Symphony CF fire. We recommend you use a Ceramic hob cleaner these are available for all leading super markets: - i.e.
  • Page 8: Section Four

    Paragon Symphony CF Users Instructions SECTIONTHREE Cleaning Continued REMOVING GLASS PANEL • Remove the trim, which is held in position with magnets. • Lift and remove the inner fascia panel. • Remove the glass fixing clamp secured with three securing nuts. Take care to support the glass panel when removing the fixing clamp.
  • Page 9 Paragon Symphony CF Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued Log Fuel Bed Layout Place rear log matrix on top of the air tray touching the rear liner and central (Lug to the right) . • Place the log shapes 1 & 2 as shown lying against the front edge of the burner.
  • Page 10 Paragon Symphony CF Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued • Position log shapes 3 and 4 as shown. • Position log shapes 5 and 6 as shown. • Position log shapes 7 and 8 as shown.
  • Page 11: Section Five

    Like all appliances incorporating an aerated burner a low frequency noise may be heard, particularly on the low setting, this is quite normal and does not affect the operation of the appliance. It is advised that a competent person service the Symphony CF fire annually. The fire is more likely to provide trouble-free operation.
  • Page 12: Installation Instructions

    Paragon Symphony CF Installation Instructions SECTION SIX Appliance Data NATURAL GAS Gas Type: CATEGORY I 2 H Gas Pressure: 20 mbar +/- 1.0mbar Pressure Test Point Location: Gas inlet elbow Gas Input: 5.5 kW Gross (Max.) 2.4kW Gross (Min.) Injectors:...
  • Page 13: Section Seven

    Paragon Symphony CF Installation Instructions SECTION SEVEN Regulations and Warnings • This appliance must only be installed in Great Britain or Ireland. • The appliance is suitable for use on natural gas only. • GB (Great Britain) This fire does not normally require purpose build ventilation.
  • Page 14: Section Eight

    Paragon Symphony CF Installation Instructions SECTION EIGHT Siting the Appliance • CLASS ONE That is a conventional brick or stone chimney as used for a solid fuel appliance with an effective cross-sectional dimension of 225 x 225 mm (9” x 9”) or a lined flue with a minimum diameter of 125mm (5”).
  • Page 15: Section Nine

    Paragon Symphony CF Installation Instructions SECTION NINE To Install the Appliance Continued GAS SUPPLY ROUTING Use rigid or semi – rigid tube to connect the supply. Determine the gas supply pipe route to the appliance before installing the fire. REMOVING GLASS PANEL •...
  • Page 16: Section Ten

    Paragon Symphony CF Installation Instructions SECTION TEN Checking Operation of Fire CHECKING GAS SOUNDNESS • Turn on the gas supply to the appliance and check for soundness in accordance with current codes of practice. • Turn off the gas supply at the external Isolation valve.
  • Page 17 Paragon Symphony CF Installation Instructions SECTION TEN Checking Operation of Fire Repeat the test with doors open and with any extractor fans in other rooms in operation. • If spillage is detected the cause must be discovered and the fault corrected, if the fault cannot be •...
  • Page 18: Section Eleven

    Paragon Symphony CF Maintenance Instructions SECTION ELEVEN Maintenance GENERAL • Servicing should be carried out annually by a competent person such as a CORGI-registered person in accordance with the relevant regulations, to ensure the safe and correct operation of the appliance.
  • Page 19: Replacement Of Oxy-Pilot Assembly

    Paragon Symphony CF Maintenance Instructions SECTION ELEVEN Maintenance Continued REPLACEMENT OF OXY-PILOT ASSEMBLY NOTE: If the pilot assembly is replaced it must be replaced by an identical unit from the same manufacturer and replaced as a complete unit. • Follow the burner tray removal sequence.
  • Page 20 7. The appliance has not been subjected to misuse or accident or been modified or repaired by any person other than the authorised employee or authorised representative of Charlton and Jenrick Ltd. 8. The registration form must be returned within 3 months of purchase. PARAGON HELPDESK NUMBER 01952 278 020 LT5245 (2:02/09)
  • Page 21: Service Log

    The following information must be complete and supported by receipts as part of the conditions of the extended three year parts warranty and the appliance must be registered by completing and returning the registration document (last page of this booklet) to Paragon Fires. Date of First annual service: Engineer Name Corgi Registration No.
  • Page 22 Post Code TELEPHO E o. PRODUCT DETAILS Model: : PARAGON SYMPHONY CF Serial No. Date of Purchase This information can be found on the label attached to the packaging and on the data badge, which is located on the appliance flange, top right behind trim.
  • Page 23 LT5245 (2:02/09)
  • Page 24 Cerrawall (2 bags) Grommet (1092) 1 X Bag of Vermiculite (4216) Glass Panel Air Tray (5183) Silicone Sealing Strip (4818) Symphony CF Inner Fascia (5230) Symphony CF Trim (5232) Battery (9V PP3) Remote Control Hand Set Battery Holder Battery Insulation Blanket...

Table of Contents