Summary of Contents for Paragon P6

  • Page 1 Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is For use in Great Britain or IRELAND only Paragon Fires Charlton & Jenrick Ltd TELFORD SHROPSHIRE TF3 3AR...
  • Page 2: Table Of Contents

    Paragon P6Instructions CONTENTS PAGE USERS INSTRUCTIONS SECTION ONE Introduction Consumer Protection Information Heath & Safety Notice Introduction Important Information SECTION TWO Operating Appliance Lighting the Appliance SECTION THREE Cleaning Cleaning Trim and Fret or Fascia Cleaning Black Painted Surfaces Cleaning Pilot Assembly...
  • Page 3: Section One Introduction

    ‘hazardous waste and should be disposed of at a site licensed for the disposal of industrial waste. INTRODUCTION  The Paragon P6 as been designed and tested to the requirements of EN 613 and is suitable for use in GB (Great Britain) and IE (Ireland). ...
  • Page 4: Important Information

    Paragon P6Users Instructions SECTION ONE Introduction Continued IMPORTANT INFORMATION  The appliance is for use on Natural Gas (G20 @ 20mbar) only.  The chimney or flue (unless new or previously used with a gas appliance) shall be swept before installation if it has been used for solid fuel.
  • Page 5: Section Two Operating Appliance

    Paragon P6Users Instructions SECTION ONE Introduction Continued  Care must be taken to prevent any damage being caused to surrounding soft furnishing or decoration; e.g. many embossed vinyl wall coverings may become discoloured if placed too close to the appliance. Combustible material i.e. wall panelling or wallpaper must be removed from behind the fire and fire fascia.
  • Page 6: Section Three Cleaning

    Paragon P6Users Instructions SECTION THREE Cleaning Warning: - Before you clean any part of the appliance ensures that the appliance is turned off and cold. CLEANING: FASCIA Abrasive or chemical cleaner should never be used. CLEANING: PAINTED SURFACES  These surfaces should be dusted regularly and any marks removed with a soft cloth.
  • Page 7 Paragon P6Users Instructions SECTIONTHREE Cleaning Continued REMOVING GLASS PANEL  Remove the five 7mm nuts holding the front glass panel retaining bracket and slide the bracket clear of the studs.  Lift the glass panel out of the bottom retaining bracket.
  • Page 8 Paragon P6Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued Place four of the log shapes on top of the air tray touching the glass back liner as shown. No 12,No 16,No 16 & No 14 Place a single layer of the bark chipping along the front edge of the air tray as shown.
  • Page 9 Paragon P6Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued Bridge two of the shape as shown. No 5 & No 8 Bridge two of the shapes as shown. No 8 & No 15 Bridge two of the shapes as shown.
  • Page 10: Section Five Appliance Data

    Paragon P6Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued  Bridge two of the shapes as shown. No 7 SECTION FIVE Appliance Data NATURAL GAS Gas Type: CATEGORY I 2 H Gas Pressure: 20 mbar +/- 1.0mbar Pressure Test Point Location:...
  • Page 11: Section Six Regulations And Warnings

    Paragon P6 Installation Instructions SECTION SIX Regulations and Warnings  This appliance must only be installed in Great Britain or Ireland.  The appliance is suitable for use on natural gas only.  GB (Great Britain) This fire does not normally require purpose build ventilation.
  • Page 12: Section Seven Siting The Appliance

    Paragon P6 Installation Instructions SECTION SEVEN Siting the Appliance MUST Please note on 125mm diameter flue system the Spigot restrictor plate be removed Class 1 Conventional Flue. The chimney must have a minimum effective height of at least 3 metres. Any permanent flue restriction or variable dampers are to be removed or locked fully open.
  • Page 13: Fitting The Closure Plate

    Paragon P6 Installation Instructions SECTION EIGHT To Install the Appliance FITTING THE CLOSURE PLATE The front of the fireplace should be flat over an area sufficient to ensure a good seal with the closure plate. The flat surface should extend for a height equal to that of the closure plate plus 20mm and for a width equal to that of the closure plate plus 40mm.
  • Page 14 Paragon P6 Installation Instructions SECTION EIGHT To Install the Appliance Continued  Fit the front glass panel within the bottom retaining bracket, position the glass panel central with the outer side edges of the panel running flush with the two side glass panels.
  • Page 15 Paragon P6 Installation Instructions SECTION NINE Checking Operation of Fire CHECKING GAS SOUNDNESS  Turn on the gas supply to the appliance and check for soundness in accordance with current codes of practice.  Turn off the gas supply at the external Isolation valve.
  • Page 16 Paragon P6 Installation Instructions SECTION NINE Checking the Operation of the fire Continued  If spillage occurs wait a further five minutes and repeat the test.  Repeat the test with doors open and with any extractor fans in other rooms in operation.
  • Page 17 Paragon P6 Installation Instructions SECTION NINE Checking the Operation of the fire Continued FITTING OPERATING LEVER  With the fascia in position pass the 4m threaded bar through the hole in the front base of the fascia.Screw the threaded bar into the end of the valve spindle.
  • Page 18: General

    Paragon P6 Maintenance Instructions SECTION TEN Maintenance GENERAL  Servicing should be carried out annually by a competent person such as a GAS SAFE-registered person in accordance with the relevant regulations, to ensure the safe and correct operation of the appliance.
  • Page 19: Replacement Of Oxy-Pilot Assembly

    Paragon P6 Maintenance Instructions SECTION TEN Maintenance Continued REPLACEMENT OF OXY-PILOT ASSEMBLY NOTE: If the pilot assembly is replaced it must be replaced by an identical unit from the same manufacturer and replaced as a complete unit.  Follow the burner tray removal sequence.
  • Page 20 7. The appliance has not been subjected to misuse or accident or been modified or repaired by any person other than the authorised employee or authorised representative of Charlton and Jenrick Ltd. 8. The registration form must be returned within 3 months of purchase. PARAGON HELPDESK NUMBER 0845 5195991 LT6488 issue 1 (06/13)
  • Page 21 For future reference we suggest you record the following details here, and keep the receipt as proof of purchase. This information may be asked for when you contact the helpdesk. Model: Paragon P6 Serial No. This information can be found on the label attached to the packaging and on the data badge, which is located on the left hand side of the base of the appliance behind trim.
  • Page 22: Service Log

    The following information must be complete and supported by receipts as part of the conditions of the extended three year parts warranty and the appliance must be registered by completing and returning the registration document (last page of this booklet) to Paragon Fires. Date of First annual service: Engineer Name Gas Safe Registration No.
  • Page 23 Post Code TELEPHONE No. PRODUCT DETAILS Model: Paragon P6 Serial No. Date of Purchase This information can be found on the label attached to the packaging and on the data badge, which is located on the left hand side of the base of the appliance behind trim.
  • Page 24 Prefix Product Serial No (NJ) A-0394 Prefix Label (Ng) Burner Tray / Box Assembly Back spigot Fitted / Restrictor Label Air Tray (Part No 6081) Glass Panels 2 x side 1 x Front Log Fuel Bed (6343) 9v Battery (1904) Control Knob Kit Bagged (6291) Spare Fixings (A-0411) Closure plate...