FINAL ASSEMBLY
Fit the fire front and trim with the 4 magnetic strips placed on the vertical side flanges of the firebox - one on the top
and one at the bottom. Offer the brass trim up squarely and centrally and push into position.
Demonstrate the lighting and extinguishing procedures to the user and the removal and refitting of the brass trim for
cleaning.
ADVISE CUSTOMER THAT:
Explain to the user that during normal use the red light may illuminate indicating a flue restriction (this may be due
to a flue obstruction or adverse wind conditions). In these circumstances the fan speed will increase and if the
condition is not corrected in approximately 10 seconds the gas supply will be shut off. The control knob must be
turned to the
position and the Off switch must be pressed to reset the control.
Before attempting to relight the fire wait 3 minutes.
The appliance should be operated with the gas control not turned on more than half-way between the
and
symbols for the first five hours of use. The curing effect of heating the coals and other refractory components will
cause an initial odour. This is due to the starch used in the manufacturing process and is non-toxic.
Any debris should be cleaned from the appliance. A vacuum cleaner can be used but only after all the loose coals have
been removed. The appliance should be serviced annually by a competent person in accordance with these
instructions and the appliance checked for spillage in accordance with the method detailed in these instructions.
Hand these instructions over to the user.
www.charltonandjenrick.co.uk
33
LT5052 (ISS 5)