Installation Guide
The AZURA® GPC Cleanup System
GPC Cleanup (Gel Permeation Chromatography) is primarily employed for general cleanup tasks on a
wide range of sample matrices such as foodstuff s, tissues, plants and environmental samples. The separa-
tion of components takes place according to their molecular weight due to the heterogeneous pore size
of the stationary phase. High-molecular substances interfering with subsequent analysis are effi ciently
removed.
Based on the versatile AZURA® device platform the GPC Cleanup System can be customized to fulfi ll spe-
cial requirements.
The AZURA® GPC Cleanup System is operated with Mobile Control Chrom. This intuitive user interface is
run on a tablet directly mounted at the system. It automatically recognizes devices and facilitates system
confi guration. Due to block programming methods are created fast with minimal number of clicks. Mobile
Control Chrom makes sample loop loading easily manageable by synchronously switching both valves at
the push of a button.
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Azura GPC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Knauer Azura GPC

  • Page 1 Installation Guide The AZURA® GPC Cleanup System GPC Cleanup (Gel Permeation Chromatography) is primarily employed for general cleanup tasks on a wide range of sample matrices such as foodstuff s, tissues, plants and environmental samples. The separa- tion of components takes place according to their molecular weight due to the heterogeneous pore size of the stationary phase.
  • Page 2 Column bypassing/selection or sample loop loading Startup The GPC Cleanup System is set up, installed and commissioned by KNAUER or a company authorized and contracted by KNAUER. For detailed information about the operation of the individual devices, please read the corresponding chapters in the respective instructions.
  • Page 3 Operating modes Note: For each loading, make sure that the same position is set for both sample loop se- A. Loading samples lection valves. If both valves are not switched 1. Set the injection valve to Load (1) position. simultaneously, the fl ow must be stopped. 2.
  • Page 4 Hegauer Weg 38 14163 Berlin, Germany to fraction bottle  Tel.: +49-(0)30-809727-0 to waste bottle Fax: +49-(0)30-8015010 E-mail: info@knauer.net Internet: www.knauer.net This document is subject to technical changes. Please go to www.knauer.net for latest version, ordering details and overview of article numbers.