32
132
Excessive temperature of cooling
blade
33
133
Overcurrent in acceleration
34
134
Overcurrent at constant speed
35
135
Overcurrent in deceleration
36
136
Undervoltage on BUS DC
37
137
Overvoltage on BUS DC
40
140
PFC Converter Fault Error in the
PFC module
41
141
Overcurrent in acceleration
42
142
Overload
43
143
Overcurrent at constant speed
44
144
Overcurrent in deceleration
45
145
Compressor not connected
correctly
46
146
No communication
47
147
Error in cooling blade
temperature sensor
51
151
Irregular condition.
54
154
Faulty reverse cycle valve
55
155
Input water high temperature
--
156
Cycle reverse due to high
temperature of discharge gas.
57
157
Read error of the remote probe
of the DHW panel.
58
158
Read error of the outside air tem-
perature probe.
WARNING
Remember that the pre-alarms are reset automatically, but the alarms must be reset manually.
From software version 3.9.0, the alarms can be reset by means of the remote ON/OFF contact, if this is enabled.
From the ON position, move to OFF then back to ON within 5 seconds to reset the alarms; a maximum of 3 resets can be made each hour via
the ON/OFF contact.
You must first reset the alarms using the "R" button.
In the event of a lack of voltage, the alarms will be reset.
72
GB
6343841_00 / Ver - 4.20
Hardware error.
Hardware error.
Hardware error.
Software error.
Software error.
Software error.
Software error.
Frequency reduced by overcurrent or overtemperature protection.
The reverse cycle valve could be faulty or blocked.
The input water temperature has exceeded the value of installer
menu parameter (H). There is probably a boiler in the same system.
With the third pre-alarm intervention, the machine goes into lockout.
This pre-alarm indicates the intervention of a defrosting cycle due to
cycle reverse, without respecting the cycle reverse times. The cycle
reverse was prompted by the capacity control threshold being excee-
ded due to the high temperature of the discharge gas (default 130°).
This pre-alarm does not cause the compressor to stop, and there is
no maximum number of interventions.
This pre-alarm indicates a fault in the remote probe, or a problem
in communication with the DHW panel. The alarm is only active if
parameter (8)=4 in the menu with password = 30.
This pre-alarm indicates a fault in the outside air temperature probe
when the DCP is present, or when the machine is a heat pump.