2) 6P Multi connector (TRIGGER)
Pin no.
CV-M10BX
1
NC
2
NC
3
GND
4
NC
5
Ext. Trigger Input
6
WEN pulse output
Note :
CV-M10 series camera generates and output WEN (Write ENable pulse
at pin no.6 of 6P Multi connector when ext. trigger pulse is input at pin
no.5 of 6P Multi connector.
WEN pulse indicates a duration time of effective video signal
generated by the operation in Random Trigger Mode and Long Time
Exposure Mode, and it is useful to set a timing with frame gabber and
other image processing equipment.
CV-M10
HA10A-1 0p-6S Hirose
CV-M10RS
TXD
RXD
GND
N C
Ext. Trigger input
WEN pulse output