Installing the System into a Rack

This section provides information on installing the SuperServer 6027B-TLF into a
rack unit. If the 6027B-TLF has already been mounted into a rack, you can skip
ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which
may mean the assembly procedure will differ slightly. The following is a guideline
for installing the 6027B-TLF into a rack with the rack rails provided. You should
also refer to the installation instructions that came with the rack unit you are using.

Identifying the Sections of the Rack Rails

You should have received two rack rail assemblies with the SuperServer 6027B-TLF.
Each of these assemblies consist of three sections: an inner fi xed chassis rail that
secures to the 6027B-TLF (A) and an outer fi xed rack rail that secures directly to
the rack itself (B). A sliding rail guide sandwiched between the two should remain
attached to the fi xed rack rail (see Figure 2-1). The A and B rails must be detached
from each other to install.
To remove the fi xed chassis rail (A), pull it out as far as possible - you should hear
a "click" sound as a locking tab emerges from inside the rail assembly and locks
the inner rail. Then depress the locking tab to pull the inner rail completely out. Do
this for both the left and right side rack rail assemblies.
Figure 2-1. Identifying the Sections of the Rack Rails
A
B
2-4