Wiring

2-5-7 Wiring Configuration for Valid External Device Monitor Function

(Example of Control Category 4 Wiring)
Connect contact b of K1 and K2 to the external device monitor inputs as shown.
● Using line synchronization setting and 8-core cable
<Using PNP output>
Gray cable
Gray cable
(with black line)
Interlock function
External device monitor function Valid
Auxiliary output
*Symbols
K1, K2: External device (forcible guide relay or magnetic conductor)
64
(Pale purple) Interlock setting input
(Brown) +V
(Pink) Test / Reset input
(Red) Auxiliary output
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Pale purple) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
Invalid (auto reset)
Can be used
Load
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
+
24V DC
+20
%
-30
K1 K2
K1
K2