Cable Wiring / Connections / Extension And Connector Pinouts - Panasonic WUME-SF4D-4 Instruction Manual

Sf4d series safety light curtain type 4
Table of Contents

Advertisement

2-5-3 Cable Wiring / Connections / Extension and Connector Pinouts

Connect the connector of the connection cable (connector on one end, connector on both ends)
to the connector of the bottom cap cable connected to the device (emitter, receiver).
Connect the wires on the other end of the connection cable as required for the application, re-
ferring to the connector pinouts below.
● If you need to extend the cable, use the special-use cable. Extension is possible to a maximum
total length of 70m each for the emitter and the receiver. If the total length is greater than 70m,
the device may malfunction, creating a risk of death or serious injury.
● When connecting in a series connection, do not exceed a total length of 70m each for the emit-
ter and the receiver, including the cable for series connection. If the total length is greater than
the specification, the device may malfunction, creating a risk of death or serious injury.
● If you are extending the synchronization + wire (orange) and synchronization - wire (orange /
black) using a cable other than the special-use cable, use 0.2mm
and extend 0V as well. For other than synchronization + wire (orange) and synchronization -
wire (orange / black), use 0.3mm
● In the case of line synchronization, emitter and receiver 0V should be common.
Bottom cap cable - discrete wire
Cable with connector on one end
B side
Side A connector (emitter/receiver common)
<5-core>
<5-core cable (SFD-CCB□-S, SFD-CB□-S, SFD-CC□-S, SFD-CCJ□-S)>
Cable color / Connector color Pin No. Lead wire color
Emitter
Gray / Gray
Gray (with Black line) /
Receiver
Black
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
2
or more cable.
<8-core>
<12-core>
1
2
3
4
5
1
2
3
4
5
WARNING
Bottom cap cable - connector
Cable with connector on both ends
B
side
Side B connector (emitter/receiver common)
<5-core>
Brown
Pink
Blue
-
Pale blue
Output polarity setting / Lockout release input
Brown
White
Blue
Black
Pale blue
Output polarity setting / Lockout release input
2
or more twisted-pair cable,
<8-core>
<12-core>
Name
24V DC
Test input
0V
-
24V DC
Control output 2 (OSSD 2)
0V
Control output 1 (OSSD 1)
Wiring
A side
A
side
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sf4d-x-01 series

Table of Contents