Wiring For Manual Reset (Interlock Is Valid) - Panasonic WUME-SF4D-4 Instruction Manual

Sf4d series safety light curtain type 4
Table of Contents

Advertisement

Wiring

2-5-5 Wiring for Manual Reset (Interlock is Valid)

(Example of Control Category 4 Wiring)
This is a common connection method whereby one emitter and one receiver face each other.
The control output (OSSD 1 / 2) turns OFF when light is blocked.
● Using line synchronization setting and 8-core cable
<Using PNP output>
Gray cable
Gray cable
(with black line)
Interlock function
External device monitor function Invalid
Auxiliary output
*Symbols
Switch S1
Vs to Vs − 2.5V (sink current 5mA or less): Emission halt (Note 1), Open: Emission
K1, K2: Safety relay unit, etc.
Notes: 1 ) Vs is the supply voltage.
2) For information on reset, refer to "3-2 Interlock Function (8-core cable, 12-core cable)".
60
(Brown) +V
(Pale purple) Interlock setting input
(Pink) Test / Reset input
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Red) Auxiliary output
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Pale purple) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
Valid (manual reset)
Not possible
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
*S1
+
24V DC
+20
%
-30
K1
K2

Advertisement