3-9 DIP Switch Settings

Some of the device settings can be changed using DIP switches.
The settings that can be changed using the DIP switches are indicated below.
<Changing settings using the DIP switches>
Item
Selects the synchronization
DIP switch 1 / 2
method.
(Emitter / Receiver)
When optical synchroniza-
Synchronization
tion is selected, you can set a
method
different frequency to reduce
mutual interference.
DIP switch 3
(Emitter)
Controls the light from the
Light emission
emitter for the change of sens-
intensity control
ing range.
function
The upper application indicator and
DIP switch 3
lower application indicator can be
(Receiver)
used as an beam axis alignment
Indicator selector
mode or an application mode.
DIP switch 4
(Emitter / Receiver)
Turns OFF the indicators re-
Power save
duce power consumption.
mode
Make sure that the power is OFF when setting DIP switch 1 / 2 (emitter / receiver) and DIP switch
3 (emitter). If DIP switch settings are changed while the power is ON, the settings will not be re-
flected. The settings will be reflected after the power is turned OFF and then turned back ON.
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
Description
Line synchronization
• DIP switch 1: OFF
• DIP switch 2: OFF
Frequency indicator (orange): "
Optical synchronization, Frequency 1
• DIP switch 1: ON
• DIP switch 2: OFF
Frequency indicator (orange): "
Optical synchronization, Frequency 2
• DIP switch 1: OFF
• DIP switch 2: ON
Frequency indicator (orange): "
Line synchronization
• DIP switch 1: ON
• DIP switch 2: ON
Frequency indicator (orange): "
Short mode
Sensing range
• DIP switch 3: OFF
Light emission intensity control indicator
(orange): "
Long mode
Sensing range
• DIP switch 3: ON
Light emission intensity control indicator
(orange): "
Beam axis alignment mode
• DIP switch 3: OFF
Application mode
• DIP switch 3: ON
Normal mode
(Allows illumination of some indicators)
• DIP switch 4: OFF
Power save mode
(Upper application indicator and lower
application indicator, Digital indicator /
received light intensity are always OFF)
• DIP switch 4: ON
CAUTION
Settings and ranges, indicator
SF4D-F□: 0.2 to 7m
SF4D-H□, SF4D-A□: 0.2 to 9m
" turns OFF
SF4D-F□: 0.8 to 12m
SF4D-H□, SF4D-A□: 0.8 to 15m
" lights
Functions
Factory default setting
" turns OFF
" lights
Line synchronization
" lights
" turns OFF
Short mode
Beam axis align-
ment mode
Normal mode
113

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sf4d-x-01 series