3-11-5 Auxiliary Output

Item
Auxiliary output opera-
tion setting
Notes: 1) Auxiliary output does not operate when the following functions are used.
• When fixed blanking function or floating blanking function is valid.
• When the muting function or override function is operating.
2) If the operation when light reception is unstable is set, auxiliary output operates after approximately 3
seconds elapses in the unstable light reception state.
3) The light received / blocked state of the sensing area is output regardless of the functions and states
below.
• Fixed blanking function, floating blanking function, muting function, override function, interlock func-
tion, lockout state
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
Description
You can change the auxiliary
output operation setting.
Settings / ranges
Control output (OSSD 1 / 2)
negative logic
Control output (OSSD 1 / 2)
positive logic
Output OFF when test input is
valid
Output ON when test input is
invalid
Output ON when test input is
valid
Output OFF when test input is
invalid
OFF when light reception is un-
stable (Note 1, 2)
ON when light reception is un-
stable (Note 1, 2)
ON during muting
OFF during muting
ON when light is received, OFF
when blocked (Note 3)
OFF when light is received, ON
when blocked (Note 3)
OFF during lockout
ON during lockout
Functions
Factory default
setting
C o n t r o l o u t p u t
(OSSD 1 / 2) nega-
tive logic
121