Functions

3-11-6 Application Indicator Function

● Normal state
Function setting
Indicator input wire
Control output
(OSSD 1 / 2)
Interlock
Test input
● Interrupt
Function setting
Lockout
Muting
Override
122
State
When input to application indi-
cator input 1
When input to application indi-
cator input 2
W h e n t h e c o n t r o l o u t p u t
(OSSD 1 / 2) turns ON
W h e n t h e c o n t r o l o u t p u t
(OSSD 1 / 2) turns OFF
When the interlock state acti-
vates
When an input signal enters
the test / reset input wire
(pink) and the test input state
activates
State
The device enters the lockout
state
When an input signal enters
the muting input A wire (yel-
low) and muting input B wire
(pink), and the device enters
the muting state
When an input signal enters
the override input wire (yel-
low) and the device enters the
override state
Color selection
Select one of blue, green, cyan,
red, magenta, orange, invalid
(turns OFF)
Select one of blue, green, cyan,
red, reddish purple, orange, in-
valid (turns OFF)
Select one of blue, green, cyan,
magenta, orange, invalid (turns
OFF)
Select one of blue, cyan, red,
magenta, orange, invalid (turns
OFF)
Select one of blue, green, cyan,
red, magenta, orange, invalid
(turns OFF)
Select one of blue, green, cyan,
red, magenta, orange, invalid
(turns OFF)
Color selection
Select red or invalid (turns OFF)
Select one of blue, green, cyan,
red, magenta, yellow, invalid
(turns OFF)
Select one of blue, green, cyan,
red, magenta, yellow, invalid
(turns OFF)
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
Illumination pattern
Select lights or blinking
Select lights or blinking
Lights
Lights
Lights
Lights
Illumination pattern
Blinking
Select lights or blinking
Select lights or blinking