Panasonic WUME-SF4D-4 Instruction Manual page 134

Sf4d series safety light curtain type 4
Table of Contents

Advertisement

Troubleshooting
["
" lights]
Synchronization error
["
" blinks]
Emitter error
["
" blinks]
Effects of noise or power sup-
ply, or internal circuit failure.
["
" blinks]
Synchronization error
<Test indicator (orange) lights up>
Test state activated. (Error
state or interlock setting er-
ror.)
Take action as indicated in the troubleshooting for the emitter and receiver. If the problem per-
sists, contact our office.
134
Cause
Mismatch between synchro-
nization method and wiring.
Synchroniza-
t i o n + w i r e
( o r a n g e ) o r
synchronization
- wire (orange /
Line synchro-
black) is short-
nization
ed or broken.
The receiver
h a s g e n e r -
ated an error.
S i g n i f i c a n t
noise outside
the specified
range is be-
Optical syn-
ing received.
chronization
C a b l e f o r
s e r i e s c o n -
nection has
failed.
The other emitter connected
in series is locked out.
The device is affected by
noise or the power supply.
An internal circuit has failed.
Receiver is in lockout state.
Cause
Digital indicator (yellow) is
blinking.
Auto reset was selected with
the test / reset input wire
(pink) open.
Manual reset was selected
with the test / reset input wire
(pink) connected to 0V or +V.
The wiring and synchronization method (line
synchronization, optical synchronization) must be
made to match. To change the synchronization
method, refer to "3-9 DIP Switch Settings".
For wiring, refer to "2-5 Wiring".
Make sure that the synchronization + wire (or-
ange) and synchronization - wire (orange / black)
are connected correctly.
Check the operation of the receiver.
Check the noise environment of the device.
Replace the cable for series connection.
Check the digital indicator (yellow) of the other
emitter connected in series.
Check the noise environment of the device.
Check the connections, supply voltage, and pow-
er supply capacity.
If you are extending the synchronization + wire
(orange) and synchronization - wire (orange /
black) using a cable other than the special-use
cable, use a 0.2mm
If the problem persists, check the number that is
blinking in the digital indicator (yellow) and the
number of times it blinks, and contact our office.
Check an digital indicator (yellow) of receiver.
Check the number shown in the digital indicator.
<Using PNP output>
Connect the test / reset input wire (pink) to + V
(brown).
<Using NPN output>
Connect the test / reset input wire (pink) to 0V
(blue).
Open the test / reset input wire (pink).
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
Remedy
2
or more twisted pair cable.
Remedy