Environmental and electrical characteristics
Start up temperature from low
temperature
Humidity
(Guaranteed)
MPR-E: Maximum allowed cable lengths for MPT Power
Unit
Table 26: Maximum allowed cable lengths for MPT Power Unit (MPR-E)
Cable type
Configuration
MPT-HC V2
MPT-HC V2 with XPIC
Constraint 1
Constraint 2
Constraint 3
MPR-A: Maximum allowed cable lengths for MPT Power
Unit
Table 27: Maximum allowed cable lengths for MPT Power Unit (MPR-A)
Cable type
Configuration
MPT-HC V2
102
Table 25: MPT Power Unit general characteristics
-40° C
0 to 95%
Required power
40 W
48 W
Maximum current in the Ethernet transformer < 1.8 A
Maximum current limit for the Power Unit: 1.8 A
Minimum MPT-HC PSU input voltage > 28 V
Data traffic only with optical cable
Required power
40 W
Coaxial cable
1AC001100022
Power only, Data
optical cable
Maximum length
510 m
440 m
Coaxial cable 1AB350440001
Power only, data on optical cable
Maximum length
300 m
Coaxial cable
1AC041350001
Power only, data
optical cable
Maximum length
220 m
190 m