Interconnect; Introduction; Power Cable Connection - Alcatel-Lucent 9500 MPR-E User Manual

Microwave packet radio
Table of Contents

Advertisement

The information contained in this section is a summary of the infor-
mation on the enclosed CD. "Refer to CD" is used throughout this sec-
tion to refer the reader to the detail information on the CD.

INTERCONNECT

3
SECTION INTRODUCTION
3.1
This section gives the location and describes, power connections, signal connections, and
status and alarm connections for the 9500 MPR.

POWER CABLE CONNECTION

3.2
See Figure 3-1 and Figure 3-2 for power cable connection. The power cable (PN 3DB18271AA)
is supplied in the MSS Installation Kit. It is supplied with the connector fitted at one end and
wire at the other. The cable is nominally 5 m (16 ft), and the wires are 4 mm
The red (or blue) wire must be connected to -48 Vdc (live); the black wire to ground/+ve.
DC power connector can be shorted inadvertently if applied at
an angle. Always insert with correct alignment.
Figure 3-1 Power Cable and Connector
2
(AWG 12).
3-1