Symptoms
Keeps cutting out
Temperature and flow control
is not very responsive
1144486-W2-K
Probable Cause
"Eco" setting enabled. Eco
reduces flow time to 5 minutes
"Warm-up" setting is enabled.
Warm-up stops the flow of
water once the shower has
reached the desired showering
temperature
"Shower run time" setting
is enabled. Shower run time
reduces the shower run time
to a user defined time
Loss of / or poor radio
communications (out of range
symbol maybe illuminated on
wireless controller).
Digital Mixing valve air locking
Digital Mixer valve box or
Wireless Controller failure
Loss of / or poor radio
communications (out of range
symbol maybe illuminated on
wireless controller).
Digital Mixer valve box or
Wireless Controller failure
38
Possible Remedy
No product fault, refer to
"using the shower" in the
Wireless Controller User
Guide book and set as
required
No product fault, refer to
"using the shower" in the
Wireless Controller User
Guide book and set as
required
No product fault, refer to
"using the shower" in the
Wireless Controller User
Guide book and set as
required
Refer to "Loss of / or poor
radio communications"
section above
Check for correct
installation practices, repeat
commissioning procedure
and rearrange pipework
to avoid airlock forming,
refer to "Typical Suitable
Installations"
Contact Kohler Mira Ltd
Refer to "Loss of / or poor radio
communications" section
above
Contact Kohler Mira Ltd