Mira Vier Installation Manual page 13

Hide thumbs Also See for Vier:
Table of Contents

Advertisement

Typical Suitable Installations:
1. Instantaneous Multipoint Water Heaters and Combination Boilers
Caution! Risk of product damage. Do not fit the Mira Digital Mixer - PUMPED
VALVE with Instantaneous Multipoint Water Heaters or Combination Boilers.
Combination
Boiler
warm
Digital Mixer
Valve (HP)
cold
hot
COLD
HOT
Only install the High Pressure Digital Mixer Valve with a multipoint gas water heater
or combination boiler of a fully modulating design (i.e. where the water draw-off
rate indirectly controls the gas flow rate to the burner).
An expansion vessel must be fitted (and regularly maintained) if any form of backflow
prevention device is fitted, e.g. Non-return valve or PRV. This will ensure that excess
expansion or pulse pressures do not damage the product or plumbing system. The
expansion vessel may already be fitted within the boiler (check with the manufacturer)
and is in addition to the normally larger central heating expansion vessel.
ISOLATE MAINS ELECTRICITY BEFORE
REMOVING COVER!
DIGITAL MIXER 2 WIRELESS
MIRA DM2 WIRELESS
HP/COMBI
1666.009
N85A
MANUFACTURED
POWER: 230 V AC
20 W
PROTECTION: IP24
MIN. SUPPLY PRESSURE: 50 kPa (0.5 bar)
MAX. WORKING PRESSURE: 500 kPa (5 bar)
MAX. STATIC PRESSURE: 1000 kPa (10 bar) (WRAS)
MAX. SUPPLY WATER TEMP: 65 °C
POSITION APPLIANCE
OR
KOHLER MIRA LTD.
CHELTENHAM
TEL: (+44) 0870 241 0888
GL52 5EP
www.mirashowers.com
HOT
COLD
F9001
Mira Vier
Shower Fittings
Key to Symbols
13
Float Valve
Isolating Valve
Pressure Reducing
Valve
Tempering Valve
Overflow Indicator
Mini Expansion Vessel
1144486-W2-K