Technical Information; Factory Settings - Worcester Greensource 9,5 Installation Manual

Air to water heat pump with domestic hot water distribution unit
Table of Contents

Advertisement

TECHNICAL INFORMATION

15
TECHNICAL INFORMATION

15.1 FACTORY SETTINGS

The table displays the factory values (F value) of the
settings that you, as a customer, (K) can change via the
customer menus Menu and Advanced menu.
The menu points in the installation and service menus (I/
S) listed in the following table become accessible to the
installer after changing the Access level, either under
menu or under Advanced menu.
Menu
Fast restart of heat pump?
Start up
_"_\Setting the clock
_"_\_"_\Set date
_"_\_"_\Set time
_"_\Connected extra sensors
_"_\_"_\T5 confirms (room temperature
sensor T5)
_"_\Air/Water pump in operation
_"_\Connection capacity (electric element)
_"_\_"_\State total output
_"_\_"_\Compressor mode, output limita-
tion
_"_\_"_\Additional heat only, output limita-
tion
_"_\Manual operation?
_"_\Additional heat options
_"_\_"_\Additional heat only?
_"_\_"_\Block additional heat?
_"_\Language
_"_\Correct sensor
_"_\Fan defrost interval
_"_\Fan defrost time
_"_\Forced defrost
_"_\Block crankcase heater at high out-
door temperature
_"_\Anti-jamming mode time
_"_\Alarm buzzer signal length
_"_\T1 Set point value maximum
_"_\Display
_"_\_"_\Contrast
_"_\_"_\Brightness
Tab. 7
46
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.co.uk 0844 556 1818
Menu
_"_\Electrical connection
_"_\Heat pump size
Room temperature setting (T5)
Temperature increase/decrease (T5)
Temperature increase/decrease settings (T5)
_"_\Limit value for V or H
Level
F-value
_"_\Change when much colder/warmer
I/S
No
_"_\Change when colder/warmer
Extra hot water
Temperatures
I/S
YY-MM-DD
Tab. 7
I/S
hh:mm:ss
Advanced menu
Temperature
I/S
No
_"_\Lowest outdoor temperature
I/S
Yes
_"_\Heating system temperature
_"_\_"_\Heat curve
I/S
13.5 kW
_"_\_"_\Hysteresis
I/S
4.5/6.75 kW
_"_\_"_\Maximum
I/S
9.0/13.5 kW
_"_\_"_\Minimum
_"_\_"_\Time factor
I/S
No
_"_\Room sensor settings (T5)
_"_\_"_\Room temperature setting
I/S
No
_"_\_"_\Room sensor influence
I/S
No
_"_\_"_\_"_\Change factor
I/S
Selected
_"_\_"_\_"_\Blocking time
I/S
0
_"_\Time limited settings
I/S
1 ggr
_"_\_"_\Time control heating
I/S
1.0 min.
_"_\_"_\_"_\Day and time
I/S
No
_"_\_"_\_"_\Change in temperature
I/S
10.0 °C
_"_\_"_\Holiday
_"_\_"_\_"_\Date
I/S
02:00
_"_\_"_\_"_\Change in temperature
I/S
1 min.
_"_\_"_\Remote control
I/S
80 °C
_"_\_"_\_"_\Remote control
_"_\_"_\_"_\Change in temperature
I/S
10
_"_\External control heating
I/S
10
Tab. 8
Level
I/S
I/S
I/S
I/S
I/S
Level
6 720 641 467 (2010/01)
F-value
230V/400V
6-11kW/
12-17kW
K
20°C
K
=
2 °C
8%
3%
K
0 h
K
F-value
K
20 °C
K
V=20.0 °C
H=45.6 °C
K
16 °C
K
4 °C
K
10
K
20 °C
K
5.0
K
4 h
K
Off
K
-10 °C
K
Off
K
-10 °C
K
Off
K
0 °C
K
Off