Advanced menu
_"_\Heating season
_"_\_"_\Heating season limit
_"_\_"_\Delay
_"_\_"_\Direct start limit
_"_\Heating, maximum operating time at
hot water demand
_"_\Shut down protection, change over
hot water to heating
_"_\Compressor working area settings
_"_\_"_\Delay after temporary stop
Hot water (T3)
_"_\Extra hot water
_"_\_"_\Number of hours
_"_\_"_\Stop temperature
_"_\Hot water peak
_"_\_"_\Interval
_"_\_"_\Start time
_"_\_"_\Stop temperature
_"_\Hot water temperature
_"_\_"_\_"_\T3 Start temperature
_"_\_"_\_"_\T8 Stop temperature
_"_\_"_\_"_\T9 Stop temperature
_"_\_"_\Additional heat only?
_"_\_"_\_"_\T3 Stop temperature
_"_\_"_\_"_\T3 Hysteresis
_"_\_"_\Hot water, maximum operating
time at heating demand
_"_\Time control hot water
_"_\Hot water additional heat
_"_\_"_\T3 Start value offset
_"_\_"_\T3 Hysteresis
Temperatures
_"_\Correct sensor
Defrost settings
_"_\T12 - T11 settings (6-11 kW)
_"_\_"_\Time for reached temperature dif-
ference
_"_\_"_\Difference at +10 °C
_"_\_"_\Difference at 0 °C
_"_\_"_\Difference at -10 °C
_"_\T12 - T11 settings (12-17 kW)
Tab. 8
6 720 641 467 (2010/01)
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.co.uk 0844 556 1818
Level
F-value
Advanced menu
_"_\_"_\Time for reached temperature dif-
ference
K
18 °C
_"_\_"_\Difference at +10 °C
K
4 h
_"_\_"_\Difference at 0 °C
K
10 °C
_"_\_"_\Differential at -10 °C
K
20 min.
_"_\Maximum outdoor temperature
I/S
300 s
_"_\T11 Maximum temperature
_"_\Maximum time
_"_\Delay after compressor start
I/S
30 min.
_"_\Minimum time between defrosts
_"_\Compressor pressure equalisation
time
K
0
_"_\4-way valve pressure equalisation time
K
65 °C
_"_\Forced defrost
_"_\Heating cable time after defrost
K
0 days
_"_\Fan defrost
K
03:00
_"_\_"_\Fan defrost interval
I/S
65.0 °C
_"_\_"_\Fan defrost time
_"_\_"_\Temperature limit
I/S
52 °C
Timers
I/S
59 °C
Additional heat settings
I/S
54 °C
_"_\Start delay
_"_\Time control additional heat
I/S
56 °C
_"_\Additional heat options
I/S
1.0 °C
_"_\_"_\Additional heat only?
K
30 min.
_"_\_"_\Block additional heat?
_"_\Electric additional heat settings
K
Off
_"_\_"_\Power guard
_"_\_"_\_"_\Power guard
I/S
5.0 °C
_"_\_"_\_"_\Supply voltage
I/S
2.0 °C
_"_\_"_\_"_\Main fuse
_"_\_"_\_"_\Display/Correction of Current
I/S
.0
transformer
_"_\_"_\_"_\Current margin
_"_\_"_\_"_\Time from tripped power guard
to possible reconnection
I/S
60 s
_"_\_"_\Connection capacity (electric element)
I/S
12 °C
_"_\_"_\_"_\State total output
I/S
8 °C
_"_\_"_\_"_\Compressor mode, output limi-
tation
I/S
6 °C
_"_\_"_\_"_\Additional heat only, output
limitation
Tab. 8
TECHNICAL INFORMATION
Level
F-value
I/S
60 s
I/S
8 °C
I/S
4 °C
I/S
2 °C
I/S
13 °C
I/S
20 °C
I/S
15 min.
I/S
10 min.
I/S
30 min.
I/S
60 s
I/S
0 s
I/S
No
I/S
15 min.
I/S
1 ggr
I/S
1.0 min.
I/S
-5 °C
I/S
60 min.
I/S
Off
I/S
No
I/S
No
I/S
Off
I/S
400 V
I/S
16 A
I/S
.0 A
I/S
0.5 A
I/S
60 s
I/S
13.5 kW
I/S
4.5/6.75 kW
I/S
9.0/13.5 kW
47