HEATING SYSTEM CONNECTION
1
Fig. 15 Typical discharge pipe arrangement
1
Safety device (e. g. temperature pressure relief valve)
2
Metal discharge pipe (D1) from temperature relief value to
tundish
3
Tundish
4
Metal discharge pipe (D2) from tundish, with continuous
fall. See 3.9d i-iv, Table 1 and worked example.
5
Fixed grating
6
Trapped gulley
7
Discharge below fixed grating (3.9d gives alternative points
of discharge)
16
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.co.uk 0844 556 1818
2
600 mm maximum
3
300 mm
maximum
4
7.4

TUNDISH (HWDU)

Fit the tundish and straight fitting G1" x 28 mm as shown
on the illustration. The tundish and fitting are supplied
together with the HWDU as part of the G3 regulations.
1
Fig. 16
1
Tundish
6 720 641 467 (2010/01)
7
5
6
6 720 641 467-75.1I
6 720 641 467-76.1I