Requirements; Product Information - Worcester Greenstar Oilfit Flexi CF Flue Installation Instructions Manual

Table of Contents

Advertisement

H Danger of death from poisoning by flue gas due
to inadequate combustion
Danger of death due to flue gas leak. If flues are
damaged or leaking, or if you smell flue gas, observe
the following rules.
▶ Close the fuel infeed.
▶ Open doors and windows.
▶ If necessary, warn all residents and leave the
building.
▶ Prevent third parties from entering the building.
▶ Rectify any damage to the flue gas pipe
immediately.
▶ Check the combustion air supply.
▶ Do not cover or reduce the size of ventilation
openings in doors, windows and walls.
▶ Ensure that there is adequate combustion air
supply, including for any appliances installed at a
later date, e.g. extractor fans, kitchen fans or air
conditioning units that discharge air to the outside.
▶ Never operate the device if there is insufficient
combustion air supply.
H Electrical work
Electrical work must only be carried out by electrical
installation contractors.
Before starting electrical work:
▶ Isolate all poles of the mains voltage and secure
against reconnection.
▶ Make sure the mains voltage is disconnected.
▶ Observe the wiring diagrams of other system
components as well.
H Packaging
The following points should be observed during
unpacking.
▶ Check the delivery immediately upon receipt for
completeness and possible transport damage.
▶ In the event of transport damage, the delivery
should only be accepted conditionally.
▶ Do not use damaged components for assembly.
▶ Carefully unpack the unit.
▶ Ensure that all packaging material is removed and
that the unit is free from all materials that may
prevent the unit from operating correctly.
Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05
1.3

Requirements

Installation
The flue installation must be fitted and terminated in accordance with
your local regulations.
Support
Flues require adequate support throughout their entire run.
Flue System
Only use the approved Oilfit flue system accessories with this flue kit.
Replacing an existing flue
When replacing an existing Oilfit flue on an appliance:
▶ Ensure it is the correct flue system for the appliance as we have
various flue systems for Floor Standing oil appliances.
▶ Ensure the flue installation meets current Building Regulation
requirements.
– Building Regulation requirements may have changed from the
original date of installation of the existing flue system.
Annual inspection
When the flue system is inspected during the annual service, the
engineer must inspect and confirm that:
▶ The flue system is continuous without any breaks.
▶ All joints in the flue system are secure and correctly assembled
according to the manufacturers instructions.
▶ The flue has a fall of 3° (52 millimetres per metre) back to the boiler.
▶ The terminal is not damaged or restricted.
▶ The plume management kit is not damaged (if fitted).
2

Product information

Conventional flexible flue liner
For use with the following Worcester Greenstar oil-fired appliances:
Utility 18/25, 32/50, 50/70
Danesmoor 18/25
Heatslave 12/18, 18/25, 25/32
Camray Kitchen 12/18, 18/25, 25/32
Camray Utility 12/18, 18/25, 25/32
Camray Utility System 12/18, 18/25, 25/32
Heatslave II 12/18, 18/25, 25/32
Danesmoor (2013) 12/18, 18/25, 25/32
Product information
3