7.9
CONNECTION PRINCIPLE OF THE
INTERNAL UNIT
The principle method of operation is based on the
vapour compression cycle with any additional heat being
provided by the built in electric heater. The control unit
regulates the heat pump in accordance with the set
heating curve with the actual temperatures captured by
outside temperature sensor T2 and flow temperature
sensor T1.
When the heat pump can no longer meet the entire
heating demand on its own, the electric additional heat
in the internal unit starts and generates the temperature
required inside the building together with the heat
pump.
primary water storage tank is not required
** G1B is not supplied and should only be used in conjunction with the Primary water storage tank.
Fig. 19 Internal unit
6 720 641 467 (2010/01)
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.co.uk 0844 556 1818
Q46
HEATING SYSTEM CONNECTION
DHW heating has priority. DHW is regulated by means of
the actual temperature captured by cylinder
temperature sensor T3. Heating is switched off via the 3-
way valve when the DHW cylinder is being heated up.
The heating system will be supplied with heating water
again once the DHW cylinder has reached its set
temperature.
Operation in extreme cold conditions:
At an outside temperatures below approx. – 20 °C, the
heat pump stops automatically and can no longer heat
DHW. Under those conditions, the additional electric
heater in the internal unit automatically takes over the
DHW heating.
E10
Radiator system
C11
Expansion vessel
C12
Primary water storage tank*
G1A
Heating system pump
G1B
**
Heating system pump
P11
Pressure gauge
Q10
Mixing valve
Q12
Isolating valve
Q13
Water outlet
E20
Heating system
E21
Heat pump
F21
Safety valve
G2
Heat carrier pump
G3
Fan
Q20
3-way valve
Q21
3-way valve
Q22
Air vent
V21
Filter heating system
E40
Tap water system
C41
Expansion vessel
E41
Hot water cylinder
V40
Hot water
W40
Cold water
F42
Temperature & pressure
relief valve
Q42
Isolation valve
Q43
Pressure reducing valve
Q44
Non return valve
Q45
Tundish
Q46
Blending valve
Sensors
T1
Heating system
sensor (indoor unit)
T2
Outdoor sensor
T3
DHW sensor
T5
Room sensor
T6
Hot gas sensor
T8
Heat pump
(outdoor unit)
T9
Heat pump return sensor
(indoor unit)
T10
Condenser
T11
Evaporator temp.
T12
Air intake
sensor
6 720 641 467-83.1I