DIMENSIONS, CLEARANCE AND PIPE CONNECTIONS

6
DIMENSIONS, CLEARANCE AND PIPE CONNECTIONS
6.1

HEAT PUMP

839
818
Fig. 10 Greensource 6-9.5 dimensions
1
Drain
2
Cable entry
3
Flow to the HWDU (hose, 1" fem. thread)
4
Return from the HWDU (hose, 1" fem. thread)
REQUIRED MINIMUM CLEARANCES FOR THE HEAT
PUMP
A minimum clearance of 1 m is required in front of the
pump; the minimum clearance to the back and sides is
0.3 m.
If a roof is installed it must be positioned at least 1.5m
above the heat pump to avoid the recirculation of cold.
12
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.co.uk 0844 556 1818
665
60
1
643
50
6 720 641 467 (2010/01)
3
4
178
147
78
2
6 720 616 817-27.1I