NVDIMM relocation guidelines

Requirements for relocating NVDIMMs or a set of NVDIMMs when the data must be preserved
The destination compute module hardware must match the original compute module hardware
configuration.
All System Utilities settings in the destination compute module must match the original System Utilities
settings in the original compute module.
If NVDIMM-Ns are used with NVDIMM Interleaving ON mode in the original compute module, do the
following:
Install the NVDIMMs in the same DIMM slots in the destination compute module.
Install the entire NVDIMM set (all the NVDIMM-Ns on the processor) on the destination compute
module.
This guideline would apply when replacing a system board due to system failure.
If any of the requirements cannot be met during NVDIMM relocation, do the following:
Manually back up the NVDIMM-N data before relocating NVDIMM-Ns to another compute module.
Relocate the NVDIMM-Ns to another compute module.
Sanitize all NVDIMM-Ns on the new compute module before using them.
Requirements for relocating NVDIMMs or a set of NVDIMMs when the data does not have to be
preserved
If data on the NVDIMM-N or set of NVDIMM-Ns does not have to be preserved, then
Move the NVDIMM-Ns to the new location and sanitize all NVDIMM-Ns after installing them to the new
location. For more information, see NVDIMM sanitization on page 42.
Observe all DIMM and NVDIMM population guidelines. For more information, see DIMM and NVDIMM
population information on page 42.
Observe the process for removing an NVDIMM.
Observe the process for installing an NVDIMM.
Review and configure the system settings for NVDIMMs. For more information, see Configuring the
compute module for NVDIMMs on page 44.

Recovering restored data from an NVDIMM-N DRAM

CAUTION:
Do not remove an NVDIMM when any LEDs on any NVDIMM in the system are illuminated. Removing
an NVDIMM when an LED is illuminated might cause a loss of data.
CAUTION:
Electrostatic discharge can damage electronic components. Be sure you are properly grounded before
beginning this procedure.
NVDIMM relocation guidelines
43