Configuration (DMX)
Use DMX configurations to operate the product with a DMX controller.
DMX Personalities
This setting allows you to choose a particular DMX personality.
1.
Go to the SETTING main level.
2.
Select the PERSONALITY programming level.
3.
Select the desired personality (UNO, DOS, or STD.P).
•
See the
each personality.
•
Make sure that the starting addresses on the various products do not overlap due to
the new personality setting.
DMX Address
In this mode, each product will respond to a unique starting address from the DMX controller. All products
with the same starting address will respond in unison.
1.
Select a DMX personality as shown in
2.
Set the starting address:
a.
Go to ADDRESS main level.
b.
Select the starting address (001–512).
The highest recommended starting address for each DMX mode is as follows:
DMX Error
These options determine what happens when DMX signal is lost or interrupted.
1.
Go to the SETTING main level.
2.
Select the DMX ERROR programming level.
3.
Select either SAVE (holds the last received DMX input) or BLACK (blacks out the product).
DMX Values
STD.P
Channel Function
1
Dimmer
2
Fine Dimmer
3
Strobe
DOS
Channel Function
1
Dimmer
2
Fine Dimmer
UNO
Channel Function
1
Dimmer
Page 14 of 28
DMX Address
section for the highest starting address you can select for
DMX
Personalities.
DMX Personality
UNO
DOS
STD.P
Value
000
255 0–100%
000
255 0–100%
000
009 Open
010
099 Strobe, slow to fast
100
109 Open
110
179 Lightning effect, slow to fast
180
189 Open
190
255 Random strobe, slow to fast
Value
000
255 0–100%
000
255 0–100%
Value
000
255 0–100%
DMX Address
512
511
510
Percent/Setting
Percent/Setting
Percent/Setting