  • Page 2 Chauvet reserves the right to revise the content of this document without any obligation to notify any person or company of such revision, however, Chauvet has no obligation to make, and does not commit to make, any such revisions. Download the latest version from www.chauvetprofessional.com.
  • Page 3: Table Of Contents

    Control Panel Operation................9 Control Options ..................... 9 Programming....................9 Configuration (DMX) ..................9 DMX Personalities......................Starting Address......................Menu Map ..................... 10 DMX Values ....................12 17Ch..........................15Ch..........................14Ch..........................12Ch..........................9Ch..........................7Ch..........................5Ch..........................HSV..........................Ovation E-910FC IP User Manual Rev. 4...
  • Page 4 Back Light ........................Key Lock ........................Gobo Power ........................System Information ......................Factory Reset......................... 5. Technical Information ..............Product Maintenance ..................21 6. Technical Specifications ............Photometrics Charts ..................23 Returns.................... Contact Us ..................Ovation E-910FC IP User Manual Rev. 4...
  • Page 5: Before You Begin

    If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier immediately may invalidate your claim. In addition, keep the box and contents for inspection.
  • Page 6: Safety Notes

    • In the event of a serious operation problem, stop using this product immediately! If your Chauvet product requires service, contact Chauvet Technical Support. Expected LED Lifespan LEDs gradually decline in brightness over time, primarily because of heat. LEDs that are arranged in clusters experience higher operating temperatures than single LEDs.
  • Page 7: Introduction

    2. Introduction Description The Ovation E-910FC IP takes the high-performance, full RGBA-Lime color-mixing LED engine of the Ovation E-910FC outdoors. Chauvet’s standard shutter assembly and lenses lend familiarity and ease of use to this IP65 ERS-style fixture that offers color temperature presets of 2800 to 6500 K that match the output of a tungsten source to perfection.
  • Page 8: Product Overview

    Accessory slot Framing shutter (x4) Beam focus knobs Barrel rotation knobs Gel frame holder Ovation GR-1 IP power/signal Lens tube Barrel Light engine assembly (sold separately) Page 4 of 31 Ovation E-910FC IP User Manual Rev. 4...
  • Page 9: Product Dimensions

    Product Dimensions 11.34 in 288 mm 7.83 in 199 mm 21.85 in 555 mm 8.74 in 6.25 in 222 mm 159 mm 15.79 in 401 mm 32.32 in 821 mm Ovation E-910FC IP User Manual Rev. 4 Page 5 of 31...
  • Page 10: Setup

    Power Linking The product supports power linking. It is possible to power link up to 7 Ovation E-910FC IP products at 120 V, up to 11 products at 208 V, or up to 12 products at 230 V. This product comes with a power input cord.
  • Page 11: Remote Device Management (Rdm)

    Only loosen or tighten the bracket knobs manually. Using tools could damage the knobs. Procedure The Ovation E-910FC IP comes with a double-bracketed yoke that can be used as a floor stand or to which mounting clamps can be attached for hanging. Mounting clamps must be purchased separately. Ensure that the clamps can support the weight of this product.
  • Page 12: Manual Beam Focus Control

    Accessory Slot The Ovation E-910FC IP has an accessory slot, which holds a drop-in iris, a motorized pattern device, or various other optional accessories (sold separately). Loosen the thumbscrews on the slot cover. (Note: Do not remove the thumbscrews).
  • Page 13: Operation

    Navigates downward through the menu list or decreases the numeric value when in a <DOWN> function Control Options Set the Ovation E-910FC IP starting address in the 001–509 DMX range. This enables control of up to 12 products in the 17-channel personality. Programming Refer to the Menu Map to understand the menu options.
  • Page 14: Menu Map

    C6020-Lt Lavender C5030-Lt Blue C5020-VLt Blue C5430-Lt Blue2 C5070-Blue C5050-Md Blue C5060-Dk Blue C5690- Indigo C5080-VDk Blue C5081-VDk Blue2 C4370-Yel Green C4070-Green C4550-Turquoise C4560-Aqua C4570-Blue Green Page 10 of 31 Ovation E-910FC IP User Manual Rev. 4...
  • Page 15 Back Light Turns off display backlight after 2 minutes of 2Min inactivity Always On Display backlight remains on Lock display (Password is <UP>, <DOWN>, Key Lock <UP>, <DOWN>, <ENTER>) Ovation E-910FC IP User Manual Rev. 4 Page 11 of 31...
  • Page 16: Dmx Values

    Clockwise fast to slow Gobo rotation 191  192 Stop 193  255 Counter-clockwise slow to fast 000  010 No function Red shift 011  127 128  255 Page 12 of 31 Ovation E-910FC IP User Manual Rev. 4...
  • Page 17: 15Ch

    Clockwise fast to slow Gobo rotation 191  192 Stop 193  255 Counter-clockwise slow to fast 000  010 No function Red shift 011  127 128  255 Ovation E-910FC IP User Manual Rev. 4 Page 13 of 31...
  • Page 18: 14Ch

    Clockwise fast to slow Gobo rotator 191  192 Stop 193  255 Counter-clockwise slow to fast 000  010 No function Red shift 011  127 128  255 Page 14 of 31 Ovation E-910FC IP User Manual Rev. 4...
  • Page 19: 9Ch

    Clockwise fast to slow Gobo rotator 191  192 Stop 193  255 Counter-clockwise slow to fast 000  010 No function Red shift 011  127 128  255 Ovation E-910FC IP User Manual Rev. 4 Page 15 of 31...
  • Page 20: 5Ch

    Value 000  255 0–100% 000  127 Index 128  190 Clockwise fast to slow Gobo rotation 191  192 Stop 193  255 Counter-clockwise slow to fast Page 16 of 31 Ovation E-910FC IP User Manual Rev. 4...
  • Page 21: Virtual Color Wheel

    PERATION Virtual Color Wheel The Ovation E-910FC IP includes a feature called the Virtual Color Wheel (VCW). This feature is available as a standalone control mode for manual use and as a control channel in select DMX personalities. More than 30 premixed colors, custom blended by Chauvet engineers, are available to call up for easier programming.
  • Page 22: Configuration (Standalone)

    Press and hold <ENTER> for 3 seconds. The output intensity will increase to 100%. Press <MENU> to exit focus mode and restore the settings. Virtual Color Wheel The Ovation E-910FC IP offers more than 30 premixed colors based on gel colors. See the Virtual Color Wheel section for details on specific values.
  • Page 23: Master/Slave

    The master should be the first product in the daisy chain. Dimmer Profiles This setting determines how fast the output of the Ovation E-910FC IP changes when the output value is modified. It provides four different options to simulate the dimming curve of an incandescent lighting product.
  • Page 24: Key Lock

    Go to the Information main level. Select Fixture Hours, Version, or UID. Factory Reset This option restores the Ovation E-910FC IP to factory default settings. Go to the Reset Factory main level. Select No or Yes. Page 20 of 31...
  • Page 25: Technical Information

    Softly drag any dirt or grime to the outside of the transparent surface. Gently polish the transparent surfaces until they are free of haze and lint. Always dry the transparent surfaces carefully after cleaning them. Ovation E-910FC IP User Manual Rev. 4 Page 21 of 31...
  • Page 26: Technical Specifications

    5-pin XLR 5, 6, 9, 12, 14, 15, 17, HSV Ordering Product Name Item Code UPC Number Ovation E-910FC IP 03121497 781462218454 UL 1573 CSA C22.2 No. 166 E113093 Page 22 of 31 Ovation E-910FC IP User Manual Rev. 4...
  • Page 27: Photometrics Charts

    2.46 m 1,105 15 m 2.89 m 3.68 m 20 m 3.85 m 4.91 m 25 m 4.81 m 6.14 m 30 m 5.78 m 7.37 m Field Beam Field Ovation E-910FC IP User Manual Rev. 4 Page 23 of 31...
  • Page 28 3.35 m 15 m 5.02 m 5.02 m 20 m 6.69 m 6.69 m 25 m 8.37 m 8.37 m 30 m 10.04 m 10.04 m Field Beam Field Page 24 of 31 Ovation E-910FC IP User Manual Rev. 4...
  • Page 29 4.62 m 15 m 6.38 m 6.93 m 20 m 8.50 m 9.23 m 25 m 10.63 m 11.54 m 30 m 12.75 m 13.85 m Field Beam Field Ovation E-910FC IP User Manual Rev. 4 Page 25 of 31...
  • Page 30 6.11 m 15 m 7.48 m 9.17 m 20 m 9.97 m 12.23 m 25 m 12.47 m 15.29 m 30 m 14.96 m 18.34 m Field Beam Field Page 26 of 31 Ovation E-910FC IP User Manual Rev. 4...
  • Page 31 9.54 m 15 m 11.22 m 14.31 m 20 m 14.96 m 19.08 m 25 m 18.69 m 23.85 m 30 m 22.43 m 28.62 m Field Beam Field Ovation E-910FC IP User Manual Rev. 4 Page 27 of 31...
  • Page 32 5.27 m 8.50 m 10.34 m 25 m 5.70 m 6.58 m 10.63 m 12.93 m 30 m 6.84 m 7.90 m 12.75 m 15.52 m Field Beam Field Page 28 of 31 Ovation E-910FC IP User Manual Rev. 4...
  • Page 33 9.23 m 13.00 m 18.65 m 25 m 10.17 m 11.54 m 16.25 m 23.32 m 30 m 12.21 m 13.85 m 19.50 m 27.98 m Field Beam Field Ovation E-910FC IP User Manual Rev. 4 Page 29 of 31...
  • Page 34: Returns

    Send the merchandise prepaid, in its original box, and with its original packing and accessories. Chauvet will not issue call tags. Clearly label the package with the RMA number. Chauvet will refuse any product returned without an RMA number. Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box.