4.4 Control Circuit Specification
4.4.1 Terminal Assignment
Input Signal
Type
Terminal
STF
Contact input
STR
RH, RM, RL
SD
Reference
point
PC
10
2
Frequency
setting
4
5
Communication
Type
Terminal
RS485
NOTE
For detailed description and reference on any input or output signal refer to the
Inverter FR-D700 SC Safety stop function Instruction Manual

4.4.2 Control Circuit Terminal Layout

Recommended wire size:
2
2
0.3mm
to 0.75mm
Name
Forward rotation start
Reverse rotation start
Multi-speed selection
Contact input common (sink),
24 V DC power supply common
24 V DC power supply, contact
input common (source)
Frequency setting power supply
Frequency setting (voltage)
Frequency setting (current)
Frequency setting common
Name
PU connector
"
.
10
2
5
4
AM
A
Output Signal
Type
Terminal
Relay
A, B, C
RUN
Open collector
SE
Analog output AM
Safety Stop Signal
Terminal
Name
S1
Safety stop input (Channel 1)
S2
Safety stop input (Channel 2)
Safety monitor output
S0
(Open collector output)
SC
Safety stop input terminal common
"
Inverter FR-D700 SC Instruction Manual
RUN SE
SO
S1 S2 SC
B
C
RL
RM
RH
SD
PC
Name
Relay output (alarm output)
Inverter running
Open collector output common
Safety monitor output common
Analog voltage output
"
"