Download Print this page

WEG CFW09 Quick Start Manual page 2

Vectrue technology
Hide thumbs Also See for CFW09:

Advertisement

Power Connections and Keypad Operation:
The CFW09 Quick Start Guide is a supplement to help get the CFW09 started quickly using the most common installation
and configuration options. This CFW09 Quick Start Guide is not meant to replace the CFW09 User's Manual. For detailed
instructions, safety precautions, proper mounting, installation, configuration, and operation please refer to the CFW09
User's Guide. Warning: Only qualified personnel should plan or implement the installation, start-up, operation and
maintenance of this equipment. Personnel must read the entire CFW09 User's Guide before attempting to install, operate
or troubleshoot the CFW09.
LED Display –
indicates fault codes,
inverter status,
parameter number and
value.
Green LED - Forward
Red LED - Reverse
Figure 2 – Keypad Operation
Display
Display Description
rdy
Inverter is Ready to be Enabled
run
Inverter is Enabled
Sub
Power Supply Voltage Too Low for Inverter Operation
dCbr
Inverter in DC Braking Mode. (See P300)
Figure 1 - Power and Grounding Connections
LCD Display –
2 lines with 16
characters displays
detailed description
of all parameters
and messages.
Green LED - Local
Red LED - Remote
2
2
Key
Description
Switches the display between
parameter number and
content.
Jogs motor when pressed
Increases Speed and
Parameter number/content
Decreases Speed and
Parameter number/content
Forward/Reverse Key
Green LED = Forward
Red LED = Reverse
Starts the VFD via a
controlled acceleration ramp.
When running switches the
display between "RPM-volts-
status-torque-Hz-Amps"
Stops the VFD via a
controlled deceleration ramp.
Resets VFD after a fault trip.
Local/Remote Key
Green LED = Local Mode
Red LED = Remote Mode

Advertisement

loading

This manual is also suitable for:

Cfw090009tgz