Led Display When The Emulator Starts Up Normally - Renesas Emulation Probe M306V8T-EPB User Manual

Emulation probe for m16c/60 series m16c/6v group m306v8
Table of Contents

Advertisement

M306V8T-EPB User's Manual

2.6.3 LED Display When the Emulator Starts Up Normally

Figure 2.4 shows upper panel LED lighting status when the emulator started up properly. Check it when starting up the
emulator system.
Figure 2.4 LED display when the power turned on PC7501
Note on Memory Expansion or Microprocessor Mode:
To use the memory expansion or microprocessor mode, be sure to set pins RDY* and HOLD* so that they are
not active at startup. Otherwise the emulator system will not start up correctly.
Note on the Target Status POWER LED:
If your MCU has two or more Vcc terminals, the LED does not light unless power is supplied to all the
terminals.
Note on the Target Status CLOCK LED:
If the LED is not turned on, check the following.
(1) After powering on the PC7501 (before starting up the emulator debugger):
Make sure that the oscillator circuit board is properly installed in the PC7501 and it is oscillating normally.
(2) After the emulator debugger is started up (after the Init dialog box settings are completed):
Make sure that the oscillator selected in the Init dialog box is oscillating normally.
REJ10J0777-0100 Rev.1.00 2005.08.01
・If this LED does not light, check the voltage of the user system.
・Check that power is supplied to all the power terminals.
・When the user system is not connected, this LED does not light.
: ON
POWER
POWER
: OFF
SAFE
CLOCK
: Flashing
ERROR
RESET
RUN
WARNING
SYSTEM
TARGET
STATUS
STATUS
IMPORTANT