2.6 Turning ON the Power

2.6.1 Checking the Connections of the Emulator System

Before turning the power ON, check the connection of the interface cable with host machine, PC7501, emulation probe, and
user system.

2.6.2 Turning ON/OFF the Power

Turn ON the power of the emulator and user system as simultaneously as possible.
Turn OFF the power of the emulator and user system as simultaneously as possible.
Do not leave either the emulator or user system powered on, because of leakage current the internal circuits may be
damaged.
When turning ON the power again after shutting OFF the power, wait for about 10 seconds.
Notes on Power Supply:
The emulator's pin Vcc is connected to the user system in order to monitor user system voltage. For this reason,
the emulator cannot supply power to the user system. Therefore, provide the user system with a separate power
supply from that of the emulator.
The voltage of the user system should be as follows.
3.15 V ≤ Vcc1 = Vcc2 = Vcc3 ≤ 3.45 V
Do not change user system power supply voltage after power has been activated.
REJ10J0777-0100 Rev.1.00 2005.08.01