ELECTRICAL CONNECTION
The appliance shall be connected to a single
phase electric line rated at 120/208Vac or
120/240Vac and 60Hz frequency.
Electric power rating:
‐ 120/208Vac: 11800 Watt or 53 A max.
‐ 120/240Vac: 12900 Watt or 56 A max.
Oven heating elements power rating:
‐ Oven bake element = 2100 Watt
‐ Oven circular element = 3300 Watt
‐ Oven broil element = 3400 Watt
Induction heating elements power rating:
‐
210 induction element = 2300 – 3700 Watt
‐
180 induction element = 1850 – 3000 Watt
(nr.2 zones)
‐
145 induction element = 1400 – 2200 Watt
Install a suitable electric power supply receptacle
connection type NEMA 14‐50R able to support a
load of at least 50 A (per line) according to local
code requirements. For four or three wires power
supply connection system see diagram below.
FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R
THREE-WIRE CONN.RECEPTACLE NEMA 14-50R
Check your local code for which of the options
below should be used in grounding the
receptacle power supply connections.
OPTION 1 – FOUR Wires connection:
‐ Connect the L1 receptacle terminal to the
incoming BLACK electrical supply wire (L1‐hot
wire)
‐ Connect the L2 receptacle terminal to the
incoming RED electrical supply wire (L2‐hot
wire)
‐ Connect the NEUTRAL receptacle terminal to
the incoming NEUTRAL (WHITE) electrical
supply wire
‐ Connect the GROUND receptacle terminal to
the incoming GROUND (GREEN) electrical
supply wire
OPTION 2 ‐ THREE‐Wires connection:
‐ Connect the L1 receptacle terminal to the
incoming BLACK electrical supply wire (L1‐hot
wire)
‐ Connect the L2 receptacle terminal to the
incoming RED electrical supply wire (L2‐hot
wire)
‐ Connect the NEUTRAL with the GROUND
receptacle terminal to the incoming NEUTRAL
(WHITE) electrical supply wire
DO NOT USE EXTENSION CORDS WITH THIS
APPLIANCE AS IT MAY RESULT IN FIRE, ELECTRIC
SHOCK OR OTHER type of PERSONAL INJURY.
The appliance is equipped at the factory with an
electric supply cord set 4 wires type with ring
terminals (L1, L2, N, Ground) suitable for range
use UL/CSA listed type SRDT/DRT 2x6AWG (L1,
L2)+2x8AWG (N, G) rated 300V, 50A with fused
plug type NEMA 14‐50P; cable length 1,5 m.; in
case the supply cord set must be replaced, it shall
be replaced with an identical set having the same
technical specs and following carefully the
instructions and diagrams below:
1) Disconnect appliance from electrical power
supply receptacle
2) Slide out the appliance from installation place
to access to back enclosure panel
3) Remove back enclosure panel by removing
the 6 screws as shown below.
4) Loose strain relief by unscrewing the two
strain relief's screws as in diagram.
10