5)   Remove  damaged  supply  cord  set  by  taking 
off  the  4  electrical  connection  screws  (block 
L1, N, L2 and Ground screw, see diagram) 
6)   Insert  the  new  supply  cord  set  in  the  strain 
relief  and  lock  it  with  two  strain  relief's 
screws in suitable position. 
7)   Fix well the ring terminals G, L1, N, L2 of the 
new  supply  cord  set  as shown  in  diagram 
with its 4 screws 
8)   Re‐install  the  back  enclosure  panel  with  6 
screws 
9)   Slide  the  appliance  back  into  its  proper 
location 
10)  Re‐connect  the  appliance  to  the  electrical 
power. 
ELECTRICAL GROUNDING 
This appliance is equipped with a four‐prong plug 
for  your  protection  against  shock  hazard  and 
should  be  plugged  directly  into  a  properly 
grounded  receptacle.  Do  not  cut  or  remove  the 
grounding prong from this plug. 
ELECTRICAL SHOCK HAZARD 
Disconnect electrical power at the circuit 
breaker box or fuse box before installing the 
Provide appropriate ground for the appliance. 
Use copper conductors only. 
Failure to follow these instructions could result 
in serious injury or death 
Label all wires prior to disconnecting when 
servicing controls. Wiring errors can cause 
improper and dangerous operation. 
Verify proper operation after servicing 
APPLIANCE SERVING 
Before carrying any servicing operation 
disconnect the appliance from gas and electric 
supply and extra appliance from final 
installation place in order to have access to the 
appliance for proper servicing intervention. 
11
 
WARNING! 
appliance.  
 
CAUTION 
 
 
 
 
 
 