Wall Mount Remote Thermostat Installation; (Optional); Installation - Travis Industries ProBuilder 42 Installation Manual

42 & 54 linear gsb2
Hide thumbs Also See for ProBuilder 42:
Table of Contents

Advertisement

Wall Mount Remote Thermostat installation (optional)

Installation

If Using the Optional Blower, Install it First
The optional blower should be installed before installing the remote.
1
Remove the lower front access panel from the fireplace by reaching in behind it and loosening the
two wing nuts and (1) ¼" screw on each side of the panel that hold it in place (see fireplace manual
for details.) Lift up and then out on the panel to remove. Lay the panel face down in front of the
fireplace.
2
Remove the 4 screws that secure the dashboard to the fireplace and gently lower it to gain access to
the back side.
NOTE
There should be enough slack in the attached wires to lower the dashboard to the floor. Make sure not
to damage any off the attached wires.
3
Remove the two wires from the back of the on/off switch.
4
Remove the switch from the dashboard by depressing the tabs on the top and the bottom of the
switch housing while pressing the back of the switch forward through the hole in the dashboard.
Replace the switch with the included switch blank (see pictures below).
© Travis Industries
Installation
(for qualified installers only)
3/13/18 - 1474
57
42 & 54PB GSB2 Aust.