INSTALLATION
VENT RESTRICTOR, BAFFLE & HEAT DEFLECTOR INSTALLATION
NOTE: THE VENT RESTRICTOR & BAFFLE MUST BE INSTALLED PRIOR TO OPTIONAL BRICK PANEL INSTALLATION.
1) Determine the venting confi guration.
2) Go to venting arrangements section (in the manual) to determine if a
vent restrictor setting is required.
Note: The vent restrictor does not apply to rear vent applications.
3) Align the vent restrictor plate to the required vent restrictor position
as per the diagrams shown.
4) Once the vent restrictor plate is in the required position, secure with
2 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over
tighten. (See diagram 2).
38
Diagram 1
Diagram 2 Vent restrictor installed on top exhaust assembly
5) From inside the fi rebox, install the baffl e plate with 4 - 1/4" x 1/2 "
screws. Ensure all screws are tight, but do not over tighten.
Baffl e Plate
Note: If installing brick panels, see brick panel instructions
before proceeding to next step.
6) From inside the fi rebox, install the top heat defl ector with 2 -
1/4" x 1/2" screws. Ensure all screws are tight, but do not over
tighten.
Heat Defl ector
Regency Bellavista™ B36X Gas Fireplace
Diagram 3
Diagram 4